Continuum® Trilogy® Allofit® Vivacit-E®
14 catalogue numbers from 00-8851-012-36, listed by Zimmer, Inc., United States, under Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | OQH |
| Device type | Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3350 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K120370 |
| Record published | 2015-09-17 |
| Record revised | 2020-06-11 (version 4) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Lumen/inner diameter 28 to 40 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00-8851-012-36 | Size KK | In distribution |
| 00-8852-012-28 | Lumen/Inner Diameter 28 mm | In distribution |
| 00-8851-012-40 | Size KK | In distribution |
| 00-8851-008-28 | Lumen/Inner Diameter 28 mm | In distribution |
| 00-8851-020-32 | Size SS | In distribution |
| 00-8851-020-40 | Lumen/Inner Diameter 40 mm | In distribution |
| 00-8851-023-36 | Lumen/Inner Diameter 36 mm | In distribution |
| 00-8851-015-28 | Size NN | In distribution |
| 00-8851-013-28 | Size LL | In distribution |
| 00-8852-009-28 | Lumen/Inner Diameter 28 mm | In distribution |
| 00-8851-007-28 | Size FF | In distribution |
| 00-8851-014-32 | Size MM | In distribution |
| 00-8851-015-32 | Size NN | In distribution |
| 00-8851-013-36 | Size LL | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| G7® | Biomet Orthopedics | 61 |
| G7 Acetabular Liner | Biomet Orthopedics | 41 |
| G7® Longevity® | Zimmer, Inc. | 20 |
| Restoris Xlve | Mako Surgical Corp. | 20 |
| Continuum® Trilogy® Allofit® | Zimmer, Inc. | 17 |
| Arcos® One-piece Revision System | Biomet Orthopedics | 16 |
| G7® Vivacit-E® | Zimmer, Inc. | 15 |
| RingLoc Hip System | Biomet Orthopedics | 15 |
| Restoris | Mako Surgical Corp. | 12 |
| G7® Acetabular System | Biomet Orthopedics | 11 |
| Sirius | Biomet Orthopedics | 7 |
| G7 Osseoti Acetabular Shell | Biomet Orthopedics | 6 |
Showing 12 of 42. All products under Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.