Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented

Strt Thread CUP Impactor With Version Guide Adapt

Registry build 21.09.26
5manufacturers in China registered for this device type
7catalogue numbers in this listing
1510(k) clearance
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OQI
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
Listed by Exactech, Inc., United States
FDA product code OQI
Device type Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K182502
Record published 2022-07-28
Record revised 2026-02-09 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 28 to 36 mm

Catalogue Numbers

Catalogue numbers for Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
Catalogue number Size Status
01-007-20-0006 In distribution
121-01-04 In distribution
141-01-36 Outer Diameter 36 mm In distribution
131-02-00 In distribution
121-01-04 In distribution
153-00-02 12/14 In distribution
141-01-28 Outer Diameter 28 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 260
Epore® XO implantcast GmbH 64
G7® Biomet Orthopedics 50
InSitu Hip System Nextstep Arthropedix 50
G7 Acetabular Liner Biomet Orthopedics 47
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented implantcast GmbH 40
Novation Exactech, Inc. 37
Trinity Acetabular Hip System with ECiMa Liners Corin Limited 28
Procotyl® Prime Microport Orthopedics Inc. 25
AcuMatch Exactech, Inc. 23
Continuum® Trilogy® Allofit® Zimmer, Inc. 23
G7® Longevity® Zimmer, Inc. 23

Showing 12 of 164. All products under Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K173583 2018-03-12

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Exactech, Inc. 510(k) number 2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 42
Exactech, Inc. 510(k) number 2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 87
Exactech, Inc. 510(k) number 2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 1446
Exactech, Inc. 510(k) number 2023-11-21 Class II Packaging change control Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
Exactech, Inc. 510(k) number 2023-11-21 Class II Packaging change control Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
Exactech, Inc. 510(k) number 2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 132 devices
Exactech, Inc. 510(k) number 2021-06-29 Class II Under Investigation by firm Biolox Delta Femoral Head was packaged and labeled as 170-36-00 (36mm +0), but the device was marked as 170-36-03 (36mm +3.5). 29 devices
Exactech, Inc. 510(k) number 2021-06-29 Class II Under Investigation by firm Biolox Delta Femoral Head was packaged and labeled as 170-36-00 (36mm +0), but the device was marked as 170-36-03 (36mm +3.5). 30 devices
Exactech, Inc. 510(k) number 2007-11-01 Not classified Process control Mislabeled: A ten piece lot of 140-32-03, 12/14 BIOLOXforte Alumina Femoral Heads 32mm (1069020 – 1069029), from Ceramtec were incorrectly labeled as 140-28-03 12/14 BIOLOXforte Alumina Femoral Heads, 28mm 10 2012-05-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer