Response Spine 5.5/6.0 System
5.5/6.0 Polyaxial Reduction Pedicle Screws - Ø5.5mm, 30mm Length
Who Else Makes It
Concentrated in Jiangsu (4), Shandong (2), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Orthopediatrics, Corp, United States |
|---|---|
| FDA product code | OSH |
| Device type | Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K150600 |
| Record published | 2015-06-30 |
| Record revised | 2025-04-11 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00-1300-0435 | In distribution | |
| 00-1300-9530 | In distribution | |
| 00-1300-6435 | In distribution | |
| 00-1300-1550 | In distribution | |
| 00-1300-2965 | In distribution | |
| 00-1300-2540 | In distribution | |
| 00-1300-8655 | In distribution | |
| 00-1300-1425 | In distribution | |
| 00-1300-3911 | In distribution | |
| 00-1300-8625 | In distribution | |
| 00-1300-7530 | In distribution | |
| 00-1300-1680 | In distribution | |
| 00-1300-2725 | In distribution | |
| 00-1300-0525 | In distribution | |
| 00-1300-6655 | In distribution | |
| 00-1300-8550 | In distribution | |
| 00-1300-9430 | In distribution | |
| 00-1300-6550 | In distribution | |
| 00-1300-3045 | In distribution | |
| 00-1300-3811 | In distribution | |
| 00-1300-2855 | In distribution | |
| 00-1300-2530 | In distribution | |
| 00-1300-3012 | In distribution | |
| 00-1300-0620 | In distribution | |
| 00-1300-6555 | In distribution | |
| 00-1300-6685 | In distribution | |
| 00-1300-2865 | In distribution | |
| 00-1300-2710 | In distribution | |
| 00-1300-7440 | In distribution | |
| 00-1300-2960 | In distribution | |
| 00-1300-7640 | In distribution | |
| 00-1300-7430 | In distribution | |
| 00-1300-2660 | In distribution | |
| 00-1300-6440 | In distribution | |
| 00-1300-7540 | In distribution | |
| 00-1300-1535 | In distribution | |
| 00-1300-9645 | In distribution | |
| 00-1300-3075 | In distribution | |
| 00-1300-9620 | In distribution | |
| 00-1300-3041 | In distribution | |
| 00-1300-0635 | In distribution | |
| 00-1300-8685 | In distribution | |
| 00-1300-7425 | In distribution | |
| 00-1300-2950 | In distribution | |
| 00-1300-8660 | In distribution | |
| 00-1300-7665 | In distribution | |
| 00-1300-0770 | In distribution | |
| 00-1300-1670 | In distribution | |
| 00-1300-8520 | In distribution | |
| 00-1300-6680 | In distribution | |
| 00-1300-9440 | In distribution | |
| 00-1300-2435 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Creo | Globus Medical, Inc. | 1,821 |
| ReLine | Nuvasive, Inc. | 1,093 |
| Olympic | Astura Medical | 951 |
| Nex-D2 | Next Orthosurgical | 887 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 876 |
| Arsenal | Alphatec Spine, Inc. | 820 |
| Apex-DL Spine System | Spinecraft LLC | 691 |
| Polaris™ 4.75 Spinal System | Biomet Spine | 413 |
| Expedium | Medos International Sàrl | 400 |
| Implanet Spine System | Implanet | 386 |
| Everest® Spinal System | VB Spine LLC | 299 |
| Arsenal Deformity Spinal Fixation System | Alphatec Spine, Inc. | 258 |
Showing 12 of 73. All products under Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K130655 | 2013-05-08 |
| K121250 | 2012-06-19 |
| K120291 | 2012-04-16 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Orthopediatrics, Corp | 510(k) number | 2020-07-06 | Class II | Under Investigation by firm | Product may have incorrect laser etched alignment lines, the non-conforming laser etch may have compromised strength, lead to unintended fracture of the device | 73 units | |
| Orthopediatrics, Corp | 510(k) number | 2017-08-03 | Class II | Employee error | The 7mm diameter uniaxial pedicle screws have been color anodized with the same color utilized on 5 mm diameter screws. | 24 units | 2019-05-08 |
| Orthopediatrics, Corp | 510(k) number | 2015-11-10 | Class II | Process change control | Response Spine UniAxial Pedicle & UniAxial Reduction Pedicle Screws may have been manufactured incorrectly, thus preventing the driver from fully engaging into the hexagonal drive feature of the screw. | 102 | 2016-05-23 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.