Calibrate

LTX NANOTEC SPACER, 6 x 18 x 50 mm, 15°

Registry build 21.09.26
3manufacturers in China registered for this device type
37catalogue numbers in this listing
5510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Shandong (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OVD
Manufacturer City Province Registered as Device types
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Record

Regulatory record for Calibrate
Listed by Alphatec Spine, Inc., United States
FDA product code OVD
Device type Intervertebral Fusion Device With Integrated Fixation, Lumbar
Device class Class 2
Regulation 21 CFR 888.3080
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K242147
Record published 2024-12-09
Record revised 2025-07-14 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Length 25 to 60 mm; width 18 to 22 mm; height 6 to 8 mm; angle 15 to 30 °; outer diameter 5 to 5.5 mm
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Calibrate
Catalogue number Size Status
261-PRO-06185015-S Length 50 mm In distribution
261-PRO-06184515-S Length 45 mm In distribution
258-06226015 Height 6 mm In distribution
259-5050 Length 50 mm In distribution
261-06185015 In distribution
261-06225520 In distribution
261-PRO-06186020-S Length 60 mm In distribution
259-5525 Outer Diameter 5.5 mm In distribution
257-06224530 Width 22 mm In distribution
258-06226030 Height 6 mm In distribution
259-5535 Outer Diameter 5.5 mm In distribution
261-PRO-06185520-S Height 6 mm In distribution
261-PRO-06224520-S Width 22 mm In distribution
261-06186020-D In distribution
262-06226015 In distribution
261-06185015-D In distribution
259-5030 Length 30 mm In distribution
259-5545 Outer Diameter 5.5 mm In distribution
262-06226030 In distribution
257-06225020 Angle 20 ° In distribution
261-PRO-08226015-S Angle 15 ° In distribution
258-06186015 Width 18 mm In distribution
262-06186015 In distribution
261-06225515-D In distribution
261-PRO-06186015-S Height 6 mm In distribution
261-06225015-D In distribution
259-5060 Length 60 mm In distribution
258-06226020 Angle 20 ° In distribution
261-06185020-D In distribution
261-06224515 In distribution
257-06184515 Angle 15 ° In distribution
261-06226020-D In distribution
261-06224520 In distribution
259-5025 Outer Diameter 5 mm In distribution
261-PRO-06225515-S Width 22 mm In distribution
262-190 In distribution
261-06185515 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Sirion Astura Medical 1,465
IdentiTi Alphatec Spine, Inc. 1,372
EL Capitan Astura Medical 1,205
Zavation Zavation 1,157
Brigade Nuvasive, Inc. 1,005
Solar™ Interbody Fusion System Degen Medical 899
Zavation F3D Corpectomy Zavation 730
ROI-A Ldr Spine USA 552
Avenue L Ldr Spine USA 524
Transcend Nanotec Alphatec Spine, Inc. 485
Endoskeleton® TL Hyperlordotic nanoLOCK® Surface Technology Titan Spine, LLC 462
Base Nuvasive, Inc. 462

Showing 12 of 241. All products under Intervertebral Fusion Device With Integrated Fixation, Lumbar

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K251575 2025-09-03
K232097 2023-09-25
K203742 2021-04-09
K123993 2013-03-05
K102402 2011-03-30

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-01-26 Class II Device Design Due to reports of intraoperative graft bolt implantation breakages. 12,777 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer