Agilon® XO Retentive PE-insert for Inverse Cap
3 catalogue numbers from 38635132, listed by implantcast GmbH, Germany, under Shoulder Prosthesis, Reverse Configuration. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Stryker Trauson (Changzhou) Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Changzhou Atomic HI-Tech Radiation Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 8 |
Record
| Listed by | implantcast GmbH, Germany |
|---|---|
| FDA product code | PHX |
| Device type | Shoulder Prosthesis, Reverse Configuration |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3660 |
| Establishment | Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2020-11-18 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 38635132 | Size: Ø32mm | In distribution |
| 38635136 | Size: Ø36mm | In distribution |
| 38635140 | Size: Ø40mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 297 |
| FX V135 | Fx Shoulder Solutions SAS | 131 |
| Prima TT Glenoid | Limacorporate | 129 |
| Shoulder Innovations Inset Reverse Total Shoulder | Shoulder Innovations, Inc | 124 |
| Equinoxe | Exactech, Inc. | 123 |
| Veritas rTSA | restor3d, inc. | 112 |
| DJO Surgical | Encore Medical, L.P. | 109 |
| R1 Reverse Shoulder System | Catalyst Orthoscience Inc | 100 |
| Tornier Perform™ Humeral System | Tornier Inc. | 96 |
| MSS – Monobloc stem | Medacta International SA | 92 |
| SMR Shoulder | Limacorporate | 90 |
| Humelock II Cemented Reversible Shoulder | Fx Solutions | 83 |
Showing 12 of 232. All products under Shoulder Prosthesis, Reverse Configuration