Comprehensive

8 catalogue numbers from SSI005068, listed by Biomet Orthopedics, United States, under Shoulder Prosthesis, Reverse Configuration. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
8catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code PHX
Manufacturer City Province Registered as Device types
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Changzhou Atomic HI-Tech Radiation Co., Ltd. Changzhou Jiangsu Contract manufacturer 8

Record

Regulatory record for Comprehensive
Listed by Biomet Orthopedics, United States
FDA product code PHX
Device type Shoulder Prosthesis, Reverse Configuration
Device class Class 2
Regulation 21 CFR 888.3660
510(k) K172502
Record published 2019-04-25
Record revised 2025-05-30 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for Comprehensive
Catalogue number Size Status
SSI005068 Small In distribution
SSI005070 Large In distribution
SSI004993 Short Mini In distribution
405907 In distribution
SSI005066 Medium In distribution
SSI004998 Standard In distribution
SSI004940 In distribution
405909 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arthrex® Arthrex, Inc. 297
FX V135 Fx Shoulder Solutions SAS 131
Prima TT Glenoid Limacorporate 129
Shoulder Innovations Inset Reverse Total Shoulder Shoulder Innovations, Inc 124
Equinoxe Exactech, Inc. 123
Veritas rTSA restor3d, inc. 112
DJO Surgical Encore Medical, L.P. 109
R1 Reverse Shoulder System Catalyst Orthoscience Inc 100
Tornier Perform™ Humeral System Tornier Inc. 96
MSS – Monobloc stem Medacta International SA 92
SMR Shoulder Limacorporate 90
Humelock II Cemented Reversible Shoulder Fx Solutions 83

Showing 12 of 232. All products under Shoulder Prosthesis, Reverse Configuration

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252404 2026-04-15

Recalls Naming This Product

7 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08
Biomet, Inc. 510(k) number 2020-09-02 Class II Packaging process control Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates a 3 units 2020-12-31
Biomet, Inc. 510(k) number 2020-05-11 Class II Under Investigation by firm The product is being recalled due to the central screw drill seizing inside the Comprehensive VRS Inserter, which may lead to an extension of surgery to find a replacement device. 38 2020-11-04
Biomet, Inc. 510(k) number 2020-02-25 Class II Packaging process control Package is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters. 21 units 2020-08-05
Biomet, Inc. 510(k) number 2019-08-21 Class II Environmental control Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. 219988 units 2021-07-21
Biomet, Inc. 510(k) number 2018-12-21 Class II Packaging process control The product was potentially being packaged without a taper adapter. 52 2020-05-06
Biomet, Inc. 510(k) number 2015-01-07 Class II Process control The taper adaptor is missing from the packaging, which may result in a delay in surgery greater than 30 minutes. 11- 6 consumed, 5 with distributors 2015-10-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer