Comprehensive Instrumentation

34 catalogue numbers from 405882, listed by Biomet Orthopedics, United States, under Shoulder Prosthesis, Reverse Configuration. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
34catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code PHX
Manufacturer City Province Registered as Device types
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Changzhou Atomic HI-Tech Radiation Co., Ltd. Changzhou Jiangsu Contract manufacturer 8

Record

Regulatory record for Comprehensive Instrumentation
Listed by Biomet Orthopedics, United States
FDA product code PHX
Device type Shoulder Prosthesis, Reverse Configuration
Device class Class 2
Regulation 21 CFR 888.3660
510(k) K193373
Record published 2020-05-23
Record revised 2025-05-30 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Comprehensive Instrumentation
Catalogue number Size Status
405882 In distribution
405960 44 mm STD – 36 mm RET +3 In distribution
110029305 41 mm Ø / In distribution
405968 44 mm +10 mm – 36 mm RET +3 In distribution
405808 In distribution
110027742 In distribution
405955 44 mm +5 mm – 36 mm STD +3 In distribution
110028522 In distribution
405881 In distribution
405806 In distribution
110028879 In distribution
405965 44 mm +5 mm – 36 mm RET +3 In distribution
405800 In distribution
110028922 In distribution
405832 In distribution
110029302 36 mm Ø / In distribution
405832 In distribution
110029304 36 mm Ø / +6 mm In distribution
110025762 In distribution
110028880 In distribution
110028055 In distribution
405884 In distribution
110025762 In distribution
405902 In distribution
110017268 In distribution
405890 In distribution
110017268 In distribution
405806 In distribution
405880 In distribution
405882 In distribution
110028923 In distribution
405998 44 mm +10 – 41 mm Retentive +3 In distribution
405881 In distribution
405833 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arthrex® Arthrex, Inc. 297
FX V135 Fx Shoulder Solutions SAS 131
Prima TT Glenoid Limacorporate 129
Shoulder Innovations Inset Reverse Total Shoulder Shoulder Innovations, Inc 124
Equinoxe Exactech, Inc. 123
Veritas rTSA restor3d, inc. 112
DJO Surgical Encore Medical, L.P. 109
R1 Reverse Shoulder System Catalyst Orthoscience Inc 100
Tornier Perform™ Humeral System Tornier Inc. 96
MSS – Monobloc stem Medacta International SA 92
SMR Shoulder Limacorporate 90
Humelock II Cemented Reversible Shoulder Fx Solutions 83

Showing 12 of 232. All products under Shoulder Prosthesis, Reverse Configuration

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252404 2026-04-15

Recalls Naming This Product

23 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Comprehensive Instrumentation
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2021-01-15 Class II Labeling Change Control Zimmer Biomet is conducting a lot specific medical device recall for the Comprehensive Reverse Shoulder Central Screw, 25 MM Length. It has been determined through a complaint investigation that a 40 MM length central screw was packaged a 49 2023-03-09
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08
Biomet, Inc. 510(k) number 2020-09-02 Class II Packaging process control Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates a 3 units 2020-12-31
Biomet, Inc. 510(k) number 2020-04-17 Class II Process control Potential presence of elevated endotoxin levels that exceed the specification limit 122 units 2021-06-25
Biomet, Inc. 510(k) number 2020-03-13 Class II Under Investigation by firm There were unknown bioburden levels prior to sterilization, which may affect sterility of the product. 125 2021-07-21
Biomet, Inc. 510(k) number 2020-02-25 Class II Packaging process control Package is intended to contain one (1) baseplate and one (1) taper adapter; however, devices may be packaged with two (2) baseplates and no (0) adapters. 21 units 2020-08-05
Biomet, Inc. 510(k) number 2018-12-21 Class II Packaging process control The product was potentially being packaged without a taper adapter. 52 2020-05-06
Biomet, Inc. 510(k) number 2017-02-17 Class II Process design Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. 28,253 in total 2018-01-29
Biomet, Inc. 510(k) number 2016-12-20 Class I Device Design Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing. 4388 2017-08-29
Biomet, Inc. 510(k) number 2015-01-07 Class II Process control The taper adaptor is missing from the packaging, which may result in a delay in surgery greater than 30 minutes. 11- 6 consumed, 5 with distributors 2015-10-22
Biomet, Inc. 510(k) number 2013-05-15 Class II Device Design Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction.
When the slot on the resection guide is offset in the wrong direction, the Steinman pin that
17 2014-06-09
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 units all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products. 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1,575 all products 2013-02-21
Biomet, Inc. 510(k) number 2011-04-22 Not classified Employee error The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled. 1575 all products 2013-02-21
Biomet, Inc. 510(k) number 2010-09-13 Not classified Pending The firm received complaints regarding fracturing of the device. 45 both products 2011-07-27
Biomet, Inc. 510(k) number 2010-09-13 Not classified Pending The firm received complaints regarding fracturing of the device. 45 both products 2011-07-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer