Veritas Reverse Total Shoulder
The Veritas patient specific glenoid baseplate is a component of a reverse total shoulder replacement. It is designed from CT imaging with a patient specific backside shape and central…
The Veritas patient specific glenoid baseplate is a component of a reverse total shoulder replacement. It is designed from CT imaging with a patient specific backside shape and central fixation location to fit the planned glenoid anatomy.
The baseplate supports a glenosphere attached during surgery. Other system components include a humeral stem and polymer bearing, which together form the reverse shoulder articulation. Patient specific components are indicated only for primary shoulder replacement.
Listed Item
Patient specific glenoid baseplate – primary, small augment
Patient and Fixation Requirements
Patients require a functional deltoid muscle and suitable anatomy, with gross rotator cuff deficiency and severe arthropathy. Porous glenoid components are used uncemented with screw fixation. The system’s broader revision indications do not extend to its patient specific components.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 10 |
| Stryker Trauson (Changzhou) Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Changzhou Atomic HI-Tech Radiation Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 8 |
Record
| Listed by | restor3d, inc., United States |
|---|---|
| FDA product code | PHX |
| Device type | Shoulder Prosthesis, Reverse Configuration |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3660 |
| Establishment | Complaint-file establishment, Manufacturer |
| 510(k) | K253992 |
| Record published | 2026-07-24 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 6500-9002 | In distribution | |
| 1500-9001-P01 | In distribution | |
| 1500-9001-P02 | In distribution | |
| 6500-9003 | In distribution | |
| 6500-9001 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arthrex® | Arthrex, Inc. | 297 |
| FX V135 | Fx Shoulder Solutions SAS | 131 |
| Prima TT Glenoid | Limacorporate | 129 |
| Shoulder Innovations Inset Reverse Total Shoulder | Shoulder Innovations, Inc | 124 |
| Equinoxe | Exactech, Inc. | 123 |
| Veritas rTSA | restor3d, inc. | 112 |
| DJO Surgical | Encore Medical, L.P. | 109 |
| R1 Reverse Shoulder System | Catalyst Orthoscience Inc | 100 |
| Tornier Perform™ Humeral System | Tornier Inc. | 96 |
| MSS – Monobloc stem | Medacta International SA | 92 |
| SMR Shoulder | Limacorporate | 90 |
| Humelock II Cemented Reversible Shoulder | Fx Solutions | 83 |
Showing 12 of 232. All products under Shoulder Prosthesis, Reverse Configuration
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K260556 | 2026-07-01 |
| K253992 | 2026-05-07 |
| K243643 | 2025-05-19 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-06-30 | Class II | Device Design | Due to incorrect machining of peripheral screw hole resulting in potential for improper engagement of the peripheral screws. | 59 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.