Veritas Reverse Total Shoulder

The Veritas patient specific glenoid baseplate is a component of a reverse total shoulder replacement. It is designed from CT imaging with a patient specific backside shape and central…

Registry build 21.09.26

The Veritas patient specific glenoid baseplate is a component of a reverse total shoulder replacement. It is designed from CT imaging with a patient specific backside shape and central fixation location to fit the planned glenoid anatomy.

The baseplate supports a glenosphere attached during surgery. Other system components include a humeral stem and polymer bearing, which together form the reverse shoulder articulation. Patient specific components are indicated only for primary shoulder replacement.

Listed Item

Patient specific glenoid baseplate – primary, small augment

Patient and Fixation Requirements

Patients require a functional deltoid muscle and suitable anatomy, with gross rotator cuff deficiency and severe arthropathy. Porous glenoid components are used uncemented with screw fixation. The system’s broader revision indications do not extend to its patient specific components.

9manufacturers in China registered for this device type
5catalogue numbers in this listing
3510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code PHX
Manufacturer City Province Registered as Device types
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Stryker Trauson (Changzhou) Medical Technology Co., Ltd. Changzhou Jiangsu Contract manufacturer 3
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Changzhou Atomic HI-Tech Radiation Co., Ltd. Changzhou Jiangsu Contract manufacturer 8

Record

Regulatory record for Veritas Reverse Total Shoulder
Listed by restor3d, inc., United States
FDA product code PHX
Device type Shoulder Prosthesis, Reverse Configuration
Device class Class 2
Regulation 21 CFR 888.3660
Establishment Complaint-file establishment, Manufacturer
510(k) K253992
Record published 2026-07-24

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries expiry date, serial number

Catalogue Numbers

Catalogue numbers for Veritas Reverse Total Shoulder
Catalogue number Size Status
6500-9002 In distribution
1500-9001-P01 In distribution
1500-9001-P02 In distribution
6500-9003 In distribution
6500-9001 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arthrex® Arthrex, Inc. 297
FX V135 Fx Shoulder Solutions SAS 131
Prima TT Glenoid Limacorporate 129
Shoulder Innovations Inset Reverse Total Shoulder Shoulder Innovations, Inc 124
Equinoxe Exactech, Inc. 123
Veritas rTSA restor3d, inc. 112
DJO Surgical Encore Medical, L.P. 109
R1 Reverse Shoulder System Catalyst Orthoscience Inc 100
Tornier Perform™ Humeral System Tornier Inc. 96
MSS – Monobloc stem Medacta International SA 92
SMR Shoulder Limacorporate 90
Humelock II Cemented Reversible Shoulder Fx Solutions 83

Showing 12 of 232. All products under Shoulder Prosthesis, Reverse Configuration

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260556 2026-07-01
K253992 2026-05-07
K243643 2025-05-19

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-06-30 Class II Device Design Due to incorrect machining of peripheral screw hole resulting in potential for improper engagement of the peripheral screws. 59

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer