Instrument
22MM-25MM Reamers AND Stem Trials Triathlon Revision Instruments
Who Else Makes It
Concentrated in Jiangsu (8), Shanghai (6), Zhejiang (3). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Microport Orthorecon Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 31 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Changzhou Master Precision Tool Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 3 |
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
Showing 12 of 23. All 23 manufacturers in China registered for Reamer
Record
| Listed by | Howmedica Osteonics Corp, United States |
|---|---|
| FDA product code | HTO |
| Device type | Reamer |
| Device class | Class 1 |
| Regulation | 21 CFR 888.4540 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2017-11-13 |
| Record revised | 2022-09-16 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Lumen/inner diameter 9 to 19 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| I-K2762SB19 | Lumen/Inner Diameter 19.0 mm | In distribution |
| I-K27207516 | Diameter: 16.0 Millimeter | In distribution |
| I-K2762SB13 | Lumen/Inner Diameter 13.0 mm | In distribution |
| I-K2762SB09 | Lumen/Inner Diameter 9.0 mm | In distribution |
| I-K27207519 | Diameter: 19.0 Millimeter | In distribution |
| I-K2762SB11 | Lumen/Inner Diameter 11.0 mm | In distribution |
| I-K27207514 | Diameter: 14.0 Millimeter | In distribution |
| I-K2762SB17 | Lumen/Inner Diameter 17.0 mm | In distribution |
| 6543-7-510 | Diameter: 10.0 Millimeter | In distribution |
| 6543-7-527 | In distribution | |
| 6543-5-202 | Side: Right Medial/Left Lateral | In distribution |
| 6543-7-512 | Diameter: 12.0 Millimeter | In distribution |
| I-K27207525 | Diameter: 25.0 Millimeter | In distribution |
| I-K27207509 | Diameter: 9.0 Millimeter | In distribution |
| 6543-7-519 | Diameter: 19.0 Millimeter | In distribution |
| 6543-7-524 | Diameter: 24.0 Millimeter | In distribution |
| 6543-5-201 | Side: Left Medial/Right Lateral | In distribution |
| 6278-5-600 | In distribution | |
| I-K27207522 | Diameter: 22.0 Millimeter | In distribution |
| 6543-7-515 | Diameter: 15.0 Millimeter | In distribution |
| I-K27207521 | Diameter: 21.0 Millimeter | In distribution |
| I-K2762SB10 | Lumen/Inner Diameter 10.0 mm | In distribution |
| 6543-7-511 | Diameter: 11.0 Millimeter | In distribution |
| 6543-1-751 | In distribution | |
| 6543-7-509 | Diameter: 9.0 Millimeter | In distribution |
| I-K27207515 | Diameter: 15.0 Millimeter | In distribution |
| 6543-7-517 | Diameter: 17.0 Millimeter | In distribution |
| 6543-7-523 | Diameter: 23.0 Millimeter | In distribution |
| 6543-7-525 | Diameter: 25.0 Millimeter | In distribution |
| I-K27207512 | Diameter: 12.0 Millimeter | In distribution |
| I-K2762SB14 | Lumen/Inner Diameter 14.0 mm | In distribution |
| 6543-7-513 | Diameter: 13.0 Millimeter | In distribution |
| I-K27207513 | Diameter: 13.0 Millimeter | In distribution |
| 6543-7-521 | Diameter: 21.0 Millimeter | In distribution |
| I-K27207523 | Diameter: 23.0 Millimeter | In distribution |
| 6543-7-516 | Diameter: 16.0 Millimeter | In distribution |
| 6543-7-514 | Diameter: 14.0 Millimeter | In distribution |
| 6543-4-524 | Diameter: 24.0 Millimeter | In distribution |
| I-K27207518 | Diameter: 18.0 Millimeter | In distribution |
| 6543-7-518 | Diameter: 18.0 Millimeter | In distribution |
| I-K2762SB12 | Lumen/Inner Diameter 12.0 mm | In distribution |
| I-K27207517 | Diameter: 17.0 Millimeter | In distribution |
| I-K27207511 | Diameter: 11.0 Millimeter | In distribution |
| 6543-7-520 | Diameter: 20.0 Millimeter | In distribution |
| I-K2399PR20 | In distribution | |
| 6278-8-310 | Diameter: 10.0 Millimeter | In distribution |
| I-K27207510 | Diameter: 10.0 Millimeter | In distribution |
| 6543-8-108 | In distribution | |
| I-K2841BR00 | In distribution | |
| 6543-7-522 | Diameter: 22.0 Millimeter | In distribution |
| I-K3292BR00 | In distribution | |
| I-K27207524 | Diameter: 24.0 Millimeter | In distribution |
| I-K2762SB16 | Lumen/Inner Diameter 16.0 mm | In distribution |
| I-K27207520 | Diameter: 20.0 Millimeter | In distribution |
| 6543-6-019 | In distribution | |
| I-K2762SB15 | Lumen/Inner Diameter 15.0 mm | In distribution |
| I-K2762SB18 | Lumen/Inner Diameter 18.0 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Trigen | Smith & Nephew, Inc. | 1,029 |
| Viant Medical, LLC | Viant Medical, LLC | 825 |
| R3 | Smith & Nephew, Inc. | 287 |
| Reamer | Ortho Development Corp. | 259 |
| InSitu Hip System | Nextstep Arthropedix | 181 |
| Apex Knee System | Omni Life Science, Inc. | 162 |
| Reamer | Synthes Gmbh | 152 |
| Reclaim | Depuy (Ireland) | 138 |
| Reamer | Zimmer, Inc. | 135 |
| Endo-Model Knee System – Instruments | Waldemar Link GmbH & Co. KG | 109 |
| DJO Surgical | Encore Medical, L.P. | 108 |
| Arthrex® | Arthrex, Inc. | 105 |
Showing 12 of 1,224. All products under Reamer
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-12-23 | Not classified | Device Design | A 46mm acetabular reamer was lasermarked as a 44m reamer and distributed to the field. | 134 units | 2013-07-17 |
| 2005-08-08 | Not classified | Device Design | Stryker Orthopaedics learned that the T-handles have the potential to not engage and not attach to the reamer properly. | 22 | 2010-02-18 |
| 2005-08-08 | Not classified | Device Design | Stryker Orthopaedics learned that the T-handles have the potential to not engage and not attach to the reamer properly. | 273 | 2010-02-18 |
| 2005-04-15 | Not classified | Process control | The Xcelerate Patella Reamer Shaft Assembly and the Reamer Adapter do not mate properly. This could result in the removal of excessive bone from the patella leading to a thinner patella; a patella that does not have enough bone for adequat | 24 total | 2008-09-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.