Trigen MAX
Trigen MAX 4.3MM Short Step Drill With AO Quick Connect
Who Else Makes It
Concentrated in Jiangsu (12), Shanghai (5), Guangdong (4). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Autocam Medical Devices (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 9 |
| Aplus (Guangzhou) Medical Technology Company | Guangzhou | Guangdong | Contract manufacturer | 6 |
| Changzhou Wastonortho Medical Appliance Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 27. All 27 manufacturers in China registered for Bit, Drill
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | HTW |
| Device type | Bit, Drill |
| Device class | Class 1 |
| Regulation | 21 CFR 888.4540 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2025-05-07 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: : – |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 72800145L | Long: Long | In distribution |
| 72800145S | Step | In distribution |
| 72800142S | Short: Short | In distribution |
| 72800144S | Short: Short | In distribution |
| 72800144L | Long: Long | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Bit, Drill | Sterilmed, Inc. | 633 |
| Bit, Drill | Synthes Gmbh | 412 |
| Arthrex® | Arthrex, Inc. | 406 |
| Level ONE | KLS-Martin L.P. | 246 |
| Acumed | Acumed LLC | 205 |
| Stryker | Provision | 198 |
| Arthrex | Provision | 186 |
| Tecomet | Tecomet, Inc. | 166 |
| Synthes | Provision | 164 |
| Drill bit | Jeil Medical Corporation | 134 |
| Bit, Drill | AAP Implantate AG | 114 |
| Emerge Medical & Design | Emerge Technologies, Inc. | 110 |
Showing 12 of 1,958. All products under Bit, Drill
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-04-13 | Not classified | Packaging | Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. | 24172 units | 2015-09-22 |
| 2012-04-13 | Not classified | Packaging | Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. | 11987 units | 2015-09-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.