DJO Surgical

EMP Rev Knee, Symmetric Cone, Impactor Head, Femoral, LG

Registry build 21.09.26
18manufacturers in China registered for this device type
73catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (4), Shandong (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWA
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Showing 12 of 18. All 18 manufacturers in China registered for Impactor

Record

Regulatory record for DJO Surgical
Listed by Encore Medical, L.P., United States
FDA product code HWA
Device type Impactor
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
510(k) K171991
Record published 2024-06-11
Record revised 2026-02-09 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for DJO Surgical
Catalogue number Size Status
803-04-236 In distribution
804-02-068 In distribution
800-07-256 In distribution
803-05-131 In distribution
800-01-395 In distribution
803-04-228 In distribution
800-07-247 In distribution
S-201928 In distribution
414924 In distribution
801-03-051 In distribution
800-04-083 In distribution
803-15-002 In distribution
800-07-245 In distribution
803-04-234 In distribution
801-07-146 In distribution
804-02-036 In distribution
803-04-238 In distribution
803-03-245 In distribution
803-05-348 In distribution
803-15-003 In distribution
800-07-246 In distribution
S-201939 In distribution
803-61-031 In distribution
803-03-246 In distribution
801-07-147 In distribution
803-03-303 In distribution
801-05-041 In distribution
S-201861 In distribution
801-01-019 In distribution
800-03-021 In distribution
801-03-039 In distribution
801-01-043 In distribution
803-15-103 In distribution
801-07-145 In distribution
S-201769 In distribution
803-95-002 In distribution
800-01-311 In distribution
801-06-077 In distribution
801-04-049 In distribution
800-07-356 In distribution
800-06-009 In distribution
803-15-101 In distribution
803-15-001 In distribution
803-03-244 In distribution
803-11-103 In distribution
801-01-177 In distribution
801-06-019 In distribution
414894 In distribution
S-201773 In distribution
803-03-304 In distribution
803-04-244 In distribution
803-04-240 In distribution
803-03-305 In distribution
804-03-001 In distribution
803-73-147 In distribution
801-05-030 In distribution
804-02-002 In distribution
803-03-243 In distribution
801-04-048 In distribution
801-07-144 In distribution
801-03-052 In distribution
803-04-232 In distribution
S-201860 In distribution
801-05-065 In distribution
803-05-337 In distribution
800-01-400 In distribution
803-61-032 In distribution
414927 In distribution
803-15-109 In distribution
801-03-040 In distribution
803-00-041 In distribution
804-02-037 In distribution
804-03-051 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R3 Smith & Nephew, Inc. 153
Conserve® Microport Orthopedics Inc. 76
Impactor Synthes Gmbh 56
Innomed, Inc. Innomed, Inc. 53
Impactor Zimmer, Inc. 50
Impactor Zimmer Trabecular Metal Technology, Inc. 43
iNSitu™ Hip System Nextstep Arthropedix 41
Apex Knee System Omni Life Science, Inc. 40
DJO Surgical DJO, LLC 36
Evolution® Microport Orthopedics Inc. 35
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 35
Attune Depuy (Ireland) 31

Showing 12 of 825. All products under Impactor

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of DJO Surgical
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Encore Medical, L.P. 510(k) number 2022-12-22 Class II Labeling Change Control Tibial insert implant large boxes were labeled small and the small boxes were labeled large. If the incorrect labeling is identified this could lead to surgical delay and if the surgeon does not recognize the size discrepancy between the in 216

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-02-09 Class II Device Design During the Turon assembly, the impaction forces caused the polymer, black acetal copolymer from the Impaction Fixture to wear off on the lateral surface of the Humeral Stem titanium plasma spray coating. 297 units 2017-10-20
2017-02-09 Class II Device Design During the Turon assembly, the impaction forces caused the polymer, black acetal copolymer from the Impaction Fixture to wear off on the lateral surface of the Humeral Stem titanium plasma spray coating. 626 units 2017-10-20
2015-09-14 Class II Device Design During the assembly, the impaction forces caused the polymer, black acetal copolymer from the Impaction Fixture to wear off on the lateral surface of the Humeral Stem titanium plasma spray coating. 634 units 2016-11-04
2015-09-14 Class II Device Design During the Turon assembly, the impaction forces caused the polymer, black acetal copolymer form the Impaction Fixture to wear off on the lateral surface of the Humeral Stem titanium plasma spray coating. 277 units 2016-11-04
2007-08-09 Not classified Device Design Angled Insert Impactor may scratch Tibial Insert on the articulating surface, causing increased wear at the damaged site. 5 units. 2008-03-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer