Fibulink

Fibulink® Removal KIT

Registry build 21.09.26
15manufacturers in China registered for this device type
1catalogue number
1recall

Who Else Makes It

Concentrated in Jiangsu (6), Guangdong (4), Shanghai (2). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWB
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Microport Orthorecon Co., Ltd. Suzhou Jiangsu Contract manufacturer 31
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10
Autocam Medical Devices (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 9
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82

Showing 12 of 15. All 15 manufacturers in China registered for Extractor

Record

Regulatory record for Fibulink
Listed by Synthes Gmbh, Switzerland
FDA product code HWB
Device type Extractor
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Specification developer, Manufacturer, Exporter
Record published 2020-03-26
Record revised 2026-07-20 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Fibulink
Catalogue number Size Status
FGS-1300 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Innomed, Inc. Innomed, Inc. 639
Extractor Depuy Spine, Inc. 84
Extractor Synthes Gmbh 73
Tecomet Tecomet, Inc. 68
Shukla Acetabular Cup – S9CUP Shukla Medical 64
Shukla Nail S9NAIL Shukla Medical 38
Shukla Shoulder S9SHLDR Shukla Medical 27
Extractor Zimmer, Inc. 27
Shukla Screw S9SCREW Shukla Medical 25
Extractor Exactech, Inc. 25
Shukla Winquist 3 – MKS1017 Shukla Medical 24
Shukla Hip S9HIP Shukla Medical 23

Showing 12 of 511. All products under Extractor

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-03-19 Class II Device Design There is a potential for the connection screw of the stem extractor to break. 31 2019-04-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer