Streamline TL Spinal Fixation System
Strmln TL Yoke Capture RS Setscrew Inrtr
Who Else Makes It
Concentrated in Jiangsu (5), Zhejiang (2), Shanghai (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Microport Orthorecon Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 31 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Jiangsu Kersen Medical Instrument Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 3 |
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
Record
| Listed by | Pioneer Surgical Technology, Inc., United States |
|---|---|
| FDA product code | HWR |
| Device type | Driver, Prosthesis |
| Device class | Class 1 |
| Regulation | 21 CFR 888.4540 |
| Establishment | Contract manufacturer, Repacker / relabeller, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2020-09-25 |
| Record revised | 2026-01-29 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Distribution end date | 2024-05-26 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 724-444 | Withdrawn | |
| 724-300 | Withdrawn | |
| 724-246 | Withdrawn | |
| 722-630 | Withdrawn | |
| 724-440 | Withdrawn | |
| 724-244 | Withdrawn | |
| 722-375 | Withdrawn | |
| 724-861 | Withdrawn | |
| 02-RS-INSERTER | Withdrawn | |
| 724-112 | Withdrawn | |
| 724-918 | Withdrawn | |
| 723-877 | Withdrawn | |
| 724-538 | Withdrawn | |
| 724-008 | Withdrawn | |
| 723-858 | Withdrawn | |
| 724-252 | Withdrawn | |
| 724-387 | Withdrawn | |
| 02-SCREWINSRTR-CL | Withdrawn | |
| 02-SETSCRWINS-1 | Withdrawn | |
| 02-SCREWINSRTR | Withdrawn | |
| 02-SETSCRWINS-2 | Withdrawn | |
| 724-299 | Withdrawn | |
| 02-RS-SCREWINSRTR | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Driver, Prosthesis | Depuy Spine, Inc. | 270 |
| ACE | Ace Surgical Supply Co., Inc. | 64 |
| Expedium | Medos International Sàrl | 54 |
| Moss | Depuy Spine, Inc. | 33 |
| Acumed | Acumed LLC | 24 |
| U2 Total Knee System | United Orthopedic Corp. | 23 |
| Driver, Prosthesis | Zimmer, Inc. | 22 |
| Viper | Depuy Spine, Inc. | 21 |
| X-Mesh | Depuy Spine, Inc. | 20 |
| Driver, Prosthesis | Depuy (Ireland) | 18 |
| Invictus | Alphatec Spine, Inc. | 18 |
| General Instruments | Alphatec Spine, Inc. | 18 |
Showing 12 of 390. All products under Driver, Prosthesis
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2007-10-10 | Not classified | Component change control | The pins may come out of the instrument and, if this happens, they could fall into/remain in the patient. | 38 | 2008-03-31 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.