Columbus

Columbus REV Trial Stem D13X132 Cem.less

Registry build 21.09.26
21manufacturers in China registered for this device type
58catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (3), Zhejiang (2). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWT
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Guangzhou Clean Medical Products Manufacturing Corp Guangzhou Guangdong Contract manufacturer 5
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235

Showing 12 of 21. All 21 manufacturers in China registered for Template

Record

Regulatory record for Columbus
Listed by Aesculap AG, Germany
FDA product code HWT
Device type Template
Device class Class 1
Regulation 21 CFR 888.4800
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-04-23
Record revised 2025-11-13 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Distribution end date 2025-01-22
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Columbus
Catalogue number Size Status
NQ183R Withdrawn
NQ462R Withdrawn
NS039T Withdrawn
NS043T Withdrawn
NS005R Withdrawn
NS041T Withdrawn
NQ189R Withdrawn
NS118R Withdrawn
NQ455R Withdrawn
NS118 Withdrawn
NQ464R Withdrawn
NQ468R Withdrawn
NQ466R Withdrawn
NS006R Withdrawn
NS011R Withdrawn
NQ186R Withdrawn
NQ266K Withdrawn
NQ184R Withdrawn
NQ181R Withdrawn
NS009R Withdrawn
NQ262K Withdrawn
NS119 Withdrawn
NQ886R Withdrawn
NS040T Withdrawn
NQ467R Withdrawn
NQ465R Withdrawn
NQ452R Withdrawn
NQ461R Withdrawn
NQ463R Withdrawn
NS116 Withdrawn
NQ881R Withdrawn
NQ870R Withdrawn
NS001R Length : 9.500 MM Withdrawn
NQ887R Withdrawn
NQ875R Withdrawn
NS008R Withdrawn
NQ263K Withdrawn
NS044T Withdrawn
NQ456R Withdrawn
NQ453R Withdrawn
NS003R Withdrawn
NQ451R Withdrawn
NQ860R Withdrawn
NQ265K Withdrawn
NQ185R Withdrawn
NQ188R Withdrawn
NQ454R Withdrawn
NQ856T Withdrawn
NQ182R Withdrawn
NQ458R Withdrawn
NQ187R Withdrawn
NS042T Withdrawn
NQ457R Withdrawn
NQ855T Withdrawn
NS012R Withdrawn
NS002R Withdrawn
NS004R Withdrawn
NS007R Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Attune Depuy (Ireland) 1,385
Template Exactech, Inc. 1,277
4WEB Medical 4WEB Inc. 991
Evolution® Microport Orthopedics Inc. 966
Template Zimmer, Inc. 792
Advance® Microport Orthopedics Inc. 644
Apex Knee System Omni Life Science, Inc. 635
Profemur® Microport Orthopedics Inc. 591
Link Instruments – Trial implants and size gauges Waldemar Link GmbH & Co. KG 549
Template Synthes Gmbh 516
Optetrak Logic Exactech, Inc. 512
Template Depuy Spine, Inc. 451

Showing 12 of 2,940. All products under Template

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-08-10 Class II Mixed-up of materials/components The NS357R Vega PS Tibia Trial/Preparation Plateau size T4 may be incorrectly labeled. If the incorrect size trial is used the potential risk is implantation of the incorrect implant size which may lead to injury of ligaments, pain and pos 13 Units 2018-08-08
2012-07-12 Class II Employee error The 4 degree and 9 degree trial instruments (SJ768T-US/SJ780T-US) are correctly dimensioned, but the part number etched on the instrument may be incorrect. The 4 degree trial instrument (SJ768T-US) may be marked with the incorrect part num 5 2013-02-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer