Vega System PS

Vega PS Trial Gliding Surface T1/1+ 12MM

Registry build 21.09.26
21manufacturers in China registered for this device type
63catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (3), Zhejiang (2). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWT
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Guangzhou Clean Medical Products Manufacturing Corp Guangzhou Guangdong Contract manufacturer 5
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235

Showing 12 of 21. All 21 manufacturers in China registered for Template

Record

Regulatory record for Vega System PS
Listed by Aesculap AG, Germany
FDA product code HWT
Device type Template
Device class Class 1
Regulation 21 CFR 888.4800
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-04-24
Record revised 2025-11-13 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Distribution end date 2025-01-22
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Vega System PS
Catalogue number Size Status
NS307RM Withdrawn
NS296 Withdrawn
NS305RM Withdrawn
NS303RM Withdrawn
NS301RM Withdrawn
NS308RM Withdrawn
NS276 Withdrawn
NS316RM Withdrawn
NS318RM Withdrawn
NS350R Withdrawn
NS286 Withdrawn
NS358R Withdrawn
NS354R Withdrawn
NS282 Withdrawn
NS281 Withdrawn
NS823R Withdrawn
NS357R Withdrawn
NS825R Withdrawn
NS289 Withdrawn
NS356R Withdrawn
NS351R Withdrawn
NS349R Withdrawn
NS362R Withdrawn
NS279 Withdrawn
NS317RM Withdrawn
NS299 Withdrawn
NS822R Withdrawn
NS315RM Withdrawn
NS821R Withdrawn
NS290 Withdrawn
NS291 Withdrawn
NS280 Withdrawn
NS352R Withdrawn
NS826R Withdrawn
NS313RM Withdrawn
NS271 Withdrawn
NS355R Withdrawn
NS275 Withdrawn
NS284 Withdrawn
NS287 Withdrawn
NS312RM Withdrawn
NS295 Withdrawn
NS824R Withdrawn
NS314RM Withdrawn
NS302RM Withdrawn
NS277 Withdrawn
NS359R Withdrawn
NS365R Withdrawn
NS274 Withdrawn
NS306RM Withdrawn
NS270 Withdrawn
NS297 Withdrawn
NS272 Withdrawn
NS828R Withdrawn
NS329 Withdrawn
NS292 Withdrawn
NS311RM Withdrawn
NS361R Withdrawn
NS827R Withdrawn
NS294 Withdrawn
NS304RM Withdrawn
NS285 Withdrawn
NS353R Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Attune Depuy (Ireland) 1,385
Template Exactech, Inc. 1,277
4WEB Medical 4WEB Inc. 991
Evolution® Microport Orthopedics Inc. 966
Template Zimmer, Inc. 792
Advance® Microport Orthopedics Inc. 644
Apex Knee System Omni Life Science, Inc. 635
Profemur® Microport Orthopedics Inc. 591
Link Instruments – Trial implants and size gauges Waldemar Link GmbH & Co. KG 549
Template Synthes Gmbh 516
Optetrak Logic Exactech, Inc. 512
Template Depuy Spine, Inc. 451

Showing 12 of 2,940. All products under Template

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-08-10 Class II Mixed-up of materials/components The NS357R Vega PS Tibia Trial/Preparation Plateau size T4 may be incorrectly labeled. If the incorrect size trial is used the potential risk is implantation of the incorrect implant size which may lead to injury of ligaments, pain and pos 13 Units 2018-08-08
2012-07-12 Class II Employee error The 4 degree and 9 degree trial instruments (SJ768T-US/SJ780T-US) are correctly dimensioned, but the part number etched on the instrument may be incorrect. The 4 degree trial instrument (SJ768T-US) may be marked with the incorrect part num 5 2013-02-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer