Activ L

Activ L TIP F/Anterior Midline Marker

Registry build 21.09.26
53manufacturers in China registered for this device type
12catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LXH
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17

Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument

Record

Regulatory record for Activ L
Listed by Aesculap AG, Germany
FDA product code LXH
Device type Orthopedic Manual Surgical Instrument
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-04-23
Record revised 2025-11-20 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Distribution end date 2024-10-17
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Activ L
Catalogue number Size Status
FW952R Withdrawn
FW940R Withdrawn
FW955R Withdrawn
FW938SU Withdrawn
FW954R Withdrawn
FW944R Withdrawn
FW943R Withdrawn
FW998R Withdrawn
FW942R Withdrawn
FW951R Withdrawn
FW953R Withdrawn
FW941R Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Razek Equipamentos Razek Equipamentos Ltda 11,578
Orthopedic Manual Surgical Instrument Globus Medical, Inc. 4,784
Instrument Howmedica Osteonics Corp 4,539
Orthopedic Manual Surgical Instrument Ortho Development Corp. 4,076
Knee Instruments Medacta International SA 3,944
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 3,420
Arthrex® Arthrex, Inc. 3,106
Spine Instruments Medacta International SA 2,892
Orthopedic Manual Surgical Instrument Medtronic Sofamor Danek, Inc. 2,766
Hip Instruments Medacta International SA 1,904
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 1,756
ReLine Nuvasive, Inc. 1,208

Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-11-18 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. Redesign of removal key. 17 2024-12-23
2020-07-13 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. 16 2024-04-26
2019-11-12 Class II Device Design Nonfunctional key due to the potential for damage to the key pins cause by force of use during assembly of the tibia locking ring. 67
2013-09-20 Class II Device Design The trial insertion instrument may disassemble during use due to a potentially weak weld on then trial inserter shaft block area located near the thumb wheel. 30 2014-12-16
2012-05-09 Class II Process change control The manufacturer informed the recalling firm of a potential laser marking error in size identification on two Columbus 4-IN-1 Femoral Cutting Guide Instruments. The guides are correctly dimensioned, but the laser markings have been incorre 2 2014-01-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer