Aesculap

Screw Holding Tweezers, self-retaining, 3 1/2", (90 mm), stainless steel, non-sterile, reusable

Registry build 21.09.26
53manufacturers in China registered for this device type
294catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LXH
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17

Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument

Record

Regulatory record for Aesculap
Listed by Aesculap AG, Germany
FDA product code LXH
Device type Orthopedic Manual Surgical Instrument
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2019-06-23
Record revised 2025-11-13 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, serial number
Distribution end date 2025-10-28
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Aesculap
Catalogue number Size Per pack Status
NG644 In distribution
MG109R In distribution
NP613R In distribution
NG277 In distribution
NP587R In distribution
MG110R In distribution
FF891R In distribution
NG298 In distribution
NE441RM In distribution
NP583R In distribution
NE421R In distribution
FF912SB Length : 70.000 MM 10 In distribution
NG515 In distribution
FF909SB Length : 70.000 MM 10 In distribution
MG106R In distribution
FH480R In distribution
NE456R In distribution
NP582R In distribution
MG108R In distribution
MG104R In distribution
FF904SB Length : 70.000 MM 10 In distribution
MG101R In distribution
FF893R In distribution
FF905SB Length : 70.000 MM 10 In distribution
NP585R In distribution
NP684R In distribution
NP471R In distribution
NP749R In distribution
NP614R In distribution
MG103R In distribution
PL432R In distribution
NP586R In distribution
NE376R In distribution
NG306 In distribution
NE330R In distribution
NE347 In distribution
NE331R In distribution
NP609R In distribution
NQ268R In distribution
NP750R In distribution
NE346R In distribution
MA996R In distribution
PL435R In distribution
ND375 In distribution
NG904R In distribution
FG310R 10 In distribution
NG308 In distribution
NE442RM In distribution
LX202S In distribution
MG473R In distribution
MG107R In distribution
NE443R In distribution
LS040S In distribution
MG102R In distribution
MG105R In distribution
NP748R In distribution
KY205R In distribution
NM350R In distribution
MA023R In distribution
NE420R In distribution
NE358R In distribution
MG100R In distribution
NP604R In distribution
NP580R In distribution
NE423R In distribution
NG278 In distribution
NQ269R In distribution
FF901R In distribution
NP584R In distribution
FF903R In distribution
NT1147R Withdrawn
FW288R Withdrawn
ME588R Withdrawn
NT992R Withdrawn
NE381T Withdrawn
FW856SU Length : 87.000 MM 2 Withdrawn
NT1166R Withdrawn
NG396 Withdrawn
FW776R Withdrawn
NT006R Withdrawn
NE162R Withdrawn
FW244P Withdrawn
NF139R Withdrawn
FW243R Withdrawn
NE192R Withdrawn
NT1122R Withdrawn
NT001R Withdrawn
SZ072SU Length : 60.000 MM Withdrawn
NG937R Withdrawn
FW180R Withdrawn
NT989R Withdrawn
ME245R Withdrawn
NE199R Withdrawn
ME586R Withdrawn
NG392 Withdrawn
FW202R Withdrawn
LX045S 10 Withdrawn
FW493R Withdrawn
FW251R Withdrawn
FW170R Withdrawn
FW192R Withdrawn
NT1169R Withdrawn
NE171R Withdrawn
FW242R Withdrawn
ND844R Withdrawn
NE333R Withdrawn
FW752R Withdrawn
ND017R Withdrawn
NE163R Withdrawn
NT1127R Withdrawn
FW272R Withdrawn
NE195R Withdrawn
ME390T Withdrawn
NP597R Withdrawn
ND007R Withdrawn
FW852SU Length : 83.000 MM 2 Withdrawn
FS860M Withdrawn
FW862SU Length : 83.000 MM 2 Withdrawn
NP608R Withdrawn
NT1165R Withdrawn
ME020R Withdrawn
NT001M Withdrawn
NS837 Withdrawn
SZ074SU Length : 290.000 MM Withdrawn
NT004R Withdrawn
FW753R Withdrawn
FO025R Withdrawn
ME589R Withdrawn
NT1142R Withdrawn
FW763R Withdrawn
FS874R Withdrawn
FW236R Withdrawn
NT994R Withdrawn
NT002M Withdrawn
KY204R Withdrawn
FW861SU Length : 81.000 MM 2 Withdrawn
FW693R Withdrawn
NT1151R Withdrawn
FW279R Withdrawn
NT1143R Withdrawn
ND847R Withdrawn
ME393T Withdrawn
NT1114R Withdrawn
ME018R Withdrawn
FW755R Withdrawn
NE422R Withdrawn
FW848R Withdrawn
NT008M Withdrawn
NE198R Withdrawn
NG494 Withdrawn
NT1150R Withdrawn
FW354R Withdrawn
FW240R Withdrawn
ME015R Withdrawn
FW815T Withdrawn
ME246R Withdrawn
NT995R Withdrawn
FW274R Withdrawn
NE173R Withdrawn
FW853SU Length : 85.000 MM 2 Withdrawn
FW211R Withdrawn
FW777R Withdrawn
KT039R Withdrawn
FW203R Withdrawn
LX420R Withdrawn
NE469R Withdrawn
NT1121R Withdrawn
LX142S 10 Withdrawn
FW694R Withdrawn
FW851SU Length : 81.000 MM 2 Withdrawn
NE356R Withdrawn
FW745P Withdrawn
NT1164R Withdrawn
NT1129R Withdrawn
FM905R Withdrawn
FW814T Withdrawn
NT007R Withdrawn
FW765R Withdrawn
NP596R Withdrawn
SZ073SU Length : 150.000 MM Withdrawn
NF275R Withdrawn
NE191R Withdrawn
FW766R Withdrawn
NT1162R Withdrawn
FW355P Withdrawn
NT002R Withdrawn
NT1160R Withdrawn
SJ709R Withdrawn
NT005R Withdrawn
NG932R Withdrawn
FW184R Withdrawn
NG492 Withdrawn
NT1140R Withdrawn
NT1128R Withdrawn
NT1115SU Withdrawn
NT990R Withdrawn
FW193R Withdrawn
LX145S 10 Withdrawn
NT1145R Withdrawn
FW816T Withdrawn
FS875R Withdrawn
ME391T Withdrawn
NT007M Withdrawn
NT004M Withdrawn
FW238R Withdrawn
NG391 Withdrawn
NE334R Withdrawn
FW760R Withdrawn
LX470R Withdrawn
NE292R Withdrawn
NT1168R Withdrawn
NQ971R Withdrawn
FW181R Withdrawn
ND054R Withdrawn
FO036R Withdrawn
FW177R Withdrawn
ME392T Withdrawn
FW185R Withdrawn
LX310R Withdrawn
NE172R Withdrawn
ME587R Withdrawn
NG491 Withdrawn
ND172 Withdrawn
FS855R Withdrawn
NT1123R Withdrawn
FS853R Withdrawn
FW764R Withdrawn
NP598R Withdrawn
FW241R Withdrawn
FW183R Withdrawn
NT003R Withdrawn
FW165R Withdrawn
LX440R Withdrawn
GC405R Withdrawn
NT988R Withdrawn
FW711R Withdrawn
NT005M Withdrawn
NG516 Withdrawn
NE190R Withdrawn
NT009M Withdrawn
GB425R Withdrawn
FW287R Withdrawn
NT991R Withdrawn
FW289R Withdrawn
NG930R Withdrawn
FS871M Withdrawn
FW271R Withdrawn
NT1171R Withdrawn
NT1125R Withdrawn
FW854SU Length : 87.000 MM 2 Withdrawn

Showing 250 of 294 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Razek Equipamentos Razek Equipamentos Ltda 11,578
Orthopedic Manual Surgical Instrument Globus Medical, Inc. 4,784
Instrument Howmedica Osteonics Corp 4,539
Orthopedic Manual Surgical Instrument Ortho Development Corp. 4,076
Knee Instruments Medacta International SA 3,944
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 3,420
Arthrex® Arthrex, Inc. 3,106
Spine Instruments Medacta International SA 2,892
Orthopedic Manual Surgical Instrument Medtronic Sofamor Danek, Inc. 2,766
Hip Instruments Medacta International SA 1,904
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 1,756
ReLine Nuvasive, Inc. 1,208

Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-11-18 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. Redesign of removal key. 17 2024-12-23
2020-07-13 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. 16 2024-04-26
2019-11-12 Class II Device Design Nonfunctional key due to the potential for damage to the key pins cause by force of use during assembly of the tibia locking ring. 67
2013-09-20 Class II Device Design The trial insertion instrument may disassemble during use due to a potentially weak weld on then trial inserter shaft block area located near the thumb wheel. 30 2014-12-16
2012-05-09 Class II Process change control The manufacturer informed the recalling firm of a potential laser marking error in size identification on two Columbus 4-IN-1 Femoral Cutting Guide Instruments. The guides are correctly dimensioned, but the laser markings have been incorre 2 2014-01-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer