Columbus

Columbus Drill Sleeve D14.0 Fem.box Prep

Registry build 21.09.26
53manufacturers in China registered for this device type
119catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LXH
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17

Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument

Record

Regulatory record for Columbus
Listed by Aesculap AG, Germany
FDA product code LXH
Device type Orthopedic Manual Surgical Instrument
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-04-23
Record revised 2025-11-13 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Distribution end date 2025-10-28
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Columbus
Catalogue number Size Status
NQ502R In distribution
NQ503R In distribution
NE284 Withdrawn
NQ501R Withdrawn
NQ378R Withdrawn
NQ589R Withdrawn
NE365R Withdrawn
NQ889R Withdrawn
NQ373R Withdrawn
NQ863R Withdrawn
NQ382R Withdrawn
NQ389R Withdrawn
NE337 Withdrawn
NQ387R Withdrawn
NQ880R Withdrawn
NE339R Withdrawn
NQ893R Withdrawn
NQ883R Withdrawn
NQ492R Withdrawn
NQ384R Withdrawn
NQ449R Withdrawn
NQ997R Withdrawn
NQ884R Withdrawn
NQ473R Withdrawn
NQ500R Withdrawn
NQ390R Withdrawn
NQ375R Withdrawn
NQ988R Withdrawn
NE379R Withdrawn
NE329R Withdrawn
NQ475R Withdrawn
NQ472R Withdrawn
NQ488R Withdrawn
NQ383R Withdrawn
NQ394R Withdrawn
NQ398 Withdrawn
NQ371R Withdrawn
NQ381R Withdrawn
NQ362R Withdrawn
NQ892R Withdrawn
NQ395R Withdrawn
NQ867R Withdrawn
NQ476R Withdrawn
NQ377R Withdrawn
NQ370R Withdrawn
NE323T Withdrawn
NQ565RM Withdrawn
NQ495R Withdrawn
NQ363R Withdrawn
NE338R Withdrawn
NQ397R Withdrawn
NQ459 Withdrawn
NQ396R Withdrawn
NE361R Withdrawn
NQ861R Withdrawn
NQ998 Withdrawn
NE336 Withdrawn
NQ399RM Withdrawn
NQ385R Withdrawn
NQ873R Withdrawn
NE363R Withdrawn
NQ386R Withdrawn
NQ379R Withdrawn
NQ895R Withdrawn
NQ872R Withdrawn
NQ372R Withdrawn
NQ866R Withdrawn
NE321R Withdrawn
NQ360R Withdrawn
NQ996R Withdrawn
NQ391R Withdrawn
NQ494R Withdrawn
NQ388R Withdrawn
NE285 Withdrawn
NE327R Withdrawn
NQ392R Withdrawn
NQ562 Withdrawn
NQ561 Withdrawn
NQ498R Withdrawn
NQ380R Withdrawn
NQ485R Withdrawn
NQ364R Withdrawn
NQ460 Withdrawn
NQ560R Withdrawn
NQ470R Withdrawn
NQ591R Withdrawn
NQ376R Withdrawn
NQ365R Withdrawn
NQ010 Withdrawn
NQ471R Withdrawn
NQ487R Withdrawn
NQ493R Withdrawn
NQ491R Withdrawn
NE349R Withdrawn
NQ393R Withdrawn
NQ369R Withdrawn
NQ896R Withdrawn
NQ474R Withdrawn
NQ864R Withdrawn
NQ890R Withdrawn
NE357R Withdrawn
NE322R Withdrawn
NQ368R Withdrawn
NE359R Withdrawn
NQ366R Withdrawn
NQ374R Withdrawn
NQ869R Withdrawn
NQ486R Withdrawn
NQ565R Withdrawn
NQ590R Withdrawn
NE364R Withdrawn
NE320R Withdrawn
NQ361R Withdrawn
NQ367R Withdrawn
NE324T Withdrawn
NQ876R Withdrawn
NE326R Withdrawn
NE362R Withdrawn
NQ564R Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Razek Equipamentos Razek Equipamentos Ltda 11,578
Orthopedic Manual Surgical Instrument Globus Medical, Inc. 4,784
Instrument Howmedica Osteonics Corp 4,539
Orthopedic Manual Surgical Instrument Ortho Development Corp. 4,076
Knee Instruments Medacta International SA 3,944
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 3,420
Arthrex® Arthrex, Inc. 3,106
Spine Instruments Medacta International SA 2,892
Orthopedic Manual Surgical Instrument Medtronic Sofamor Danek, Inc. 2,766
Hip Instruments Medacta International SA 1,904
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 1,756
ReLine Nuvasive, Inc. 1,208

Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-11-18 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. Redesign of removal key. 17 2024-12-23
2020-07-13 Class II Component design/selection Fracture or breakage of the spinal fixation arm at the downtube instrument if the 90 degree angle is not met when using the removal key with the spinal fixation system. 16 2024-04-26
2019-11-12 Class II Device Design Nonfunctional key due to the potential for damage to the key pins cause by force of use during assembly of the tibia locking ring. 67
2013-09-20 Class II Device Design The trial insertion instrument may disassemble during use due to a potentially weak weld on then trial inserter shaft block area located near the thumb wheel. 30 2014-12-16
2012-05-09 Class II Process change control The manufacturer informed the recalling firm of a potential laser marking error in size identification on two Columbus 4-IN-1 Femoral Cutting Guide Instruments. The guides are correctly dimensioned, but the laser markings have been incorre 2 2014-01-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer