Healicoil

Healicoil Regenesorb 4.75 MM Threaded Dilator, Reusable

Registry build 21.09.26
53manufacturers in China registered for this device type
3catalogue numbers in this listing
1510(k) clearance
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LXH
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17

Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument

Record

Regulatory record for Healicoil
Listed by Smith & Nephew, Inc., United States
FDA product code LXH
Device type Orthopedic Manual Surgical Instrument
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2015-08-29
Record revised 2023-09-07 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Healicoil
Catalogue number Size Status
72203709 In distribution
72203710 In distribution
72202621 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Razek Equipamentos Razek Equipamentos Ltda 11,578
Orthopedic Manual Surgical Instrument Globus Medical, Inc. 4,784
Instrument Howmedica Osteonics Corp 4,539
Orthopedic Manual Surgical Instrument Ortho Development Corp. 4,076
Knee Instruments Medacta International SA 3,944
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 3,420
Arthrex® Arthrex, Inc. 3,106
Spine Instruments Medacta International SA 2,892
Orthopedic Manual Surgical Instrument Medtronic Sofamor Danek, Inc. 2,766
Hip Instruments Medacta International SA 1,904
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 1,756
ReLine Nuvasive, Inc. 1,208

Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K001507 2000-06-14

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-06-29 Class II Process design The 4.5MM PeriLoc Targeter right hand part was anodized green and was marked as a left-hand part. 3 units 2022-02-18
2019-10-07 Class II Process control LAG SCREW 3.2 GUIDE PIN SLEEVE are being recalled due to a manufacturing error. The detent balls in the guide pin sleeve were not drilled to the correct depth, which will cause them to not fully compress. 116 devices 2023-03-08
2019-01-07 Class II Process control The pin that holds the spring mechanism is not properly mounted. The pin could potentially disassemble. 72 units 2020-09-17
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 927 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 3435 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 8195 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 44 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1203 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 739 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 867 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1434 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1300 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1693 units 2015-09-22
2011-07-07 Not classified Nonconforming Material/Component Shaft tip (casting) does not meet the SNE 416
specification, which could result in rusting of the Tendon Strippers
570 units 2015-07-23
2010-04-20 Not classified Process control Markings for the drill guides are on the incorrect side: left is printed on right side and right is printed on the left side 12 units 2011-12-07
2009-01-22 Not classified Process design Incorrect depth gauge mark etched onto guide wire pin. Guide pin is too long. 99 units 2011-08-18
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 2 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 4 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 8 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 21 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 42 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 8 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 30 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 6 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 12 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 9 units 2010-02-02
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 4 units 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2006-08-29 Not classified Other Tibial punches were not manufactured to specification and could break at the tip during use. 4800 units 2010-04-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer