Journey

Journey Articular Insert Trial BCS Standard 7-8 Right 15MM

Registry build 21.09.26
53manufacturers in China registered for this device type
220catalogue numbers in this listing
1510(k) clearance
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LXH
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Suzhou Jinsheng Plastic Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17

Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument

Record

Regulatory record for Journey
Listed by Smith & Nephew, Inc., United States
FDA product code LXH
Device type Orthopedic Manual Surgical Instrument
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2015-08-29
Record revised 2023-09-07 (version 10)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number
Distribution end date 2022-03-17

Catalogue Numbers

Catalogue numbers for Journey
Catalogue number Size Status
74010087KT In distribution
E0015098-2 In distribution
74013764 In distribution
74033252 In distribution
74013752 In distribution
74033251 In distribution
74010079KT In distribution
74010041KL In distribution
74033125 In distribution
74033287 In distribution
74018603 In distribution
E0015006-1 In distribution
74013753 In distribution
74033255 In distribution
74036111 In distribution
74033142 In distribution
74013773 In distribution
74033143 In distribution
74033268 In distribution
74013746 In distribution
74033134 In distribution
74010120KT In distribution
74033214 In distribution
74010121KT In distribution
74010095KT In distribution
E0015202-1 In distribution
74033238 In distribution
74010119KT In distribution
74010096KT In distribution
74033246 In distribution
74010093KT In distribution
74010030KT In distribution
74033244 In distribution
E0015265-1 In distribution
74033111 In distribution
74013776 In distribution
74033227 In distribution
74010083KT In distribution
74010111KT In distribution
74033121 In distribution
E0014891-2 In distribution
74014434 In distribution
71935115 In distribution
74033256 In distribution
74010033KT In distribution
74033133 In distribution
74033245 In distribution
74033218 In distribution
74013760 In distribution
E0015214-1 In distribution
74018601 In distribution
74016436 In distribution
74033275 In distribution
74010088KT In distribution
74033262 In distribution
74033286 In distribution
74010090KT In distribution
74013771 In distribution
74010085KT In distribution
74033277 In distribution
74013772 In distribution
74036138 In distribution
74013766 In distribution
74033112 In distribution
74033257 In distribution
74010089KT In distribution
74010008 In distribution
74013769 In distribution
74013759 In distribution
74033248 In distribution
74033228 In distribution
74010080KT In distribution
74036110 In distribution
74010105KT In distribution
71935113 In distribution
74033113 In distribution
74010097KT In distribution
74010058KT In distribution
74033213 In distribution
74013754 In distribution
E0015171-1 In distribution
71935188 In distribution
74010076KT In distribution
74033241 In distribution
74016472 In distribution
74010114KT In distribution
74013750 In distribution
74033237 In distribution
71932926 In distribution
74013770 In distribution
74013758 In distribution
74013768 In distribution
74011821 In distribution
74010056KT In distribution
74010115KT In distribution
74010123KT In distribution
74033284 In distribution
E0015288-1 In distribution
74010012KT In distribution
E0015287-1 In distribution
74010109KT In distribution
74010081KT In distribution
74033223 In distribution
74033224 In distribution
74033141 In distribution
E0015366-1 In distribution
74010112KT In distribution
74013774 In distribution
74016424 In distribution
74014432 In distribution
74033258 In distribution
74010117KT In distribution
74033145 In distribution
74033115 In distribution
74013761 In distribution
E0016863-1 In distribution
E0014920-1 In distribution
74033124 In distribution
74033288 In distribution
74033266 In distribution
74033217 In distribution
71932925 In distribution
74033123 In distribution
74010106KT In distribution
74033271 In distribution
74033273 In distribution
74033216 In distribution
74036131 In distribution
74033222 In distribution
74033254 In distribution
74010031KT In distribution
74033232 In distribution
74013763 In distribution
74033211 In distribution
E0015098-1 In distribution
74033282 In distribution
74036158 In distribution
74010014 In distribution
71935146 In distribution
71932924 In distribution
74036132 In distribution
74033283 In distribution
74010084KT In distribution
E0014983-1 In distribution
74014429 In distribution
74010107KT In distribution
74033233 In distribution
E0016863-2 In distribution
71935144 In distribution
71932927 In distribution
74010099KT In distribution
74013767 In distribution
74033226 In distribution
74033264 In distribution
74010122KT In distribution
74036133 In distribution
74033285 In distribution
74010069KT In distribution
74033131 In distribution
74033212 In distribution
74010055KT In distribution
74010094KT In distribution
74033276 In distribution
74033278 In distribution
74033242 In distribution
74033243 In distribution
74010032KT In distribution
74033267 In distribution
74010124KT In distribution
74013762 In distribution
74010116KT In distribution
74018609 In distribution
74033253 In distribution
74010100KT In distribution
74033272 In distribution
74010077KT In distribution
74014433 In distribution
74013748 In distribution
74033234 In distribution
71935143 In distribution
74033261 In distribution
74010082KT In distribution
71935145 In distribution
74012821 In distribution
74033221 In distribution
74033132 In distribution
74033235 In distribution
74014431 In distribution
74010118KT In distribution
74010078KT In distribution
74033247 In distribution
E0015266-1 In distribution
71935189 In distribution
74033215 In distribution
74033135 In distribution
74010092KT In distribution
E0015182-1 In distribution
74033281 In distribution
74010010 In distribution
74033263 In distribution
74033231 In distribution
74010110KT In distribution
74013775 In distribution
74033122 In distribution
74010108KT In distribution
74033114 In distribution
74010098KT In distribution
74033225 In distribution
E0015028-1 In distribution
74033236 In distribution
74010091KT In distribution
74033265 In distribution
74033274 In distribution
E0015078-1 In distribution
74033144 In distribution
74016435 In distribution
71935114 In distribution
74010113KT Withdrawn
E0014976-1 Withdrawn
E0014887-1 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Razek Equipamentos Razek Equipamentos Ltda 11,578
Orthopedic Manual Surgical Instrument Globus Medical, Inc. 4,784
Instrument Howmedica Osteonics Corp 4,539
Orthopedic Manual Surgical Instrument Ortho Development Corp. 4,076
Knee Instruments Medacta International SA 3,944
Kyocera Medical Technologies, Inc. Kyocera Medical Technologies, Inc. 3,420
Arthrex® Arthrex, Inc. 3,106
Spine Instruments Medacta International SA 2,892
Orthopedic Manual Surgical Instrument Medtronic Sofamor Danek, Inc. 2,766
Hip Instruments Medacta International SA 1,904
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 1,756
ReLine Nuvasive, Inc. 1,208

Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K001507 2000-06-14

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-06-29 Class II Process design The 4.5MM PeriLoc Targeter right hand part was anodized green and was marked as a left-hand part. 3 units 2022-02-18
2019-10-07 Class II Process control LAG SCREW 3.2 GUIDE PIN SLEEVE are being recalled due to a manufacturing error. The detent balls in the guide pin sleeve were not drilled to the correct depth, which will cause them to not fully compress. 116 devices 2023-03-08
2019-01-07 Class II Process control The pin that holds the spring mechanism is not properly mounted. The pin could potentially disassemble. 72 units 2020-09-17
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 927 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 3435 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 8195 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 44 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1203 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 739 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 867 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1434 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1300 units 2015-09-22
2012-04-13 Not classified Packaging Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility. 1693 units 2015-09-22
2011-07-07 Not classified Nonconforming Material/Component Shaft tip (casting) does not meet the SNE 416
specification, which could result in rusting of the Tendon Strippers
570 units 2015-07-23
2010-04-20 Not classified Process control Markings for the drill guides are on the incorrect side: left is printed on right side and right is printed on the left side 12 units 2011-12-07
2009-01-22 Not classified Process design Incorrect depth gauge mark etched onto guide wire pin. Guide pin is too long. 99 units 2011-08-18
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 2 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 4 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 8 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 21 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 42 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 8 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 10 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 30 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 1 unit 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 6 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 12 units 2010-02-02
2007-07-12 Not classified Packaging process control The carton label may not reflect the correct size of the acetabular cup. 9 units 2010-02-02
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 4 units 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2007-03-13 Not classified Other The carton label reads BHR Acetabular Cup 60mm contained a 58mm cup. 1 unit 2011-10-28
2006-08-29 Not classified Other Tibial punches were not manufactured to specification and could break at the tip during use. 4800 units 2010-04-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer