Straightshot
STRAIGHTSHOT LIGAMENT GRAFT PASSER/PROTECTOR 8.5mm
Who Else Makes It
Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| B.Braun Medical (Suzhou) Co,.Ltd | Suzhou | Jiangsu | Contract manufacturer | 37 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Suzhou Jinsheng Plastic Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument
Record
| Listed by | DePuy Mitek, Inc., United States |
|---|---|
| FDA product code | LXH |
| Device type | Orthopedic Manual Surgical Instrument |
| Device class | Class 1 |
| Regulation | 21 CFR 888.4540 |
| Establishment | Specification developer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2015-09-01 |
| Record revised | 2026-03-26 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Package of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 270130 | In distribution | |
| 232205 | In distribution | |
| 270129 | In distribution | |
| 232210 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Razek Equipamentos | Razek Equipamentos Ltda | 11,578 |
| Orthopedic Manual Surgical Instrument | Globus Medical, Inc. | 4,784 |
| Instrument | Howmedica Osteonics Corp | 4,539 |
| Orthopedic Manual Surgical Instrument | Ortho Development Corp. | 4,076 |
| Knee Instruments | Medacta International SA | 3,944 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 3,420 |
| Arthrex® | Arthrex, Inc. | 3,106 |
| Spine Instruments | Medacta International SA | 2,892 |
| Orthopedic Manual Surgical Instrument | Medtronic Sofamor Danek, Inc. | 2,766 |
| Hip Instruments | Medacta International SA | 1,904 |
| Medtronic Reusable Instruments | Medtronic Sofamor Danek, Inc. | 1,756 |
| ReLine | Nuvasive, Inc. | 1,208 |
Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-02-24 | Class II | Employee error | Device is missing the pin in the graft loader component. | US: 131 units; OUS: 312 units | |
| 2025-02-24 | Class II | Employee error | Device is missing the pin in the graft loader component. | US: 131 units; OUS: 312 units | |
| 2018-08-30 | Class II | Under Investigation by firm | The device has an offset in the design that results in a reading approximately 3.2mm shorter than the actual length of the bone hole. | 401 | 2020-06-05 |
| 2017-12-22 | Class II | Process control | Reports of product loosening or coming unscrewed from the handle. | 84 | 2019-07-16 |
| 2011-06-27 | Not classified | Process change control | Quick Disconnect Ratchet Handle may slip up the driver shaft or disengage leaving the shaft in the screw head. | 75 units | 2012-01-19 |
| 2005-08-09 | Not classified | Other | Mislabeled: The kit contained the incorrect Ligament Passer. The package contained a 9.5 mm instead of the labeled 11.5mm ligament passer | 5 boxes /10 units (50 pieces) | 2006-05-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.