The Locking Pediatric Osteotomy Plate (LolliPOP) System
Lollipop Derotation PIN Ø2.8 - Package OF 2
Who Else Makes It
Concentrated in Jiangsu (24), Guangdong (7), Zhejiang (6). 29 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| B.Braun Medical (Suzhou) Co,.Ltd | Suzhou | Jiangsu | Contract manufacturer | 37 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Suzhou Jinsheng Plastic Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
Showing 12 of 53. All 53 manufacturers in China registered for Orthopedic Manual Surgical Instrument
Record
| Listed by | Orthopediatrics Canada ULC, Canada |
|---|---|
| FDA product code | LXH |
| Device type | Orthopedic Manual Surgical Instrument |
| Device class | Class 1 |
| Regulation | 21 CFR 888.4540 |
| Establishment | Manufacturer |
| Premarket notification | Exempt |
| Record published | 2020-08-12 |
| Record revised | 2025-05-13 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Storage | Special storage condition: keep at room temperature |
| Sizes | Outer diameter 2 to 2.8 mm; length 229 to 254 mm; lumen/inner diameter 2.2 to 3.4 mm |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| POP-VBC125 | In distribution | ||
| POP-GWR128-PKG2 | Outer Diameter 2.8 mm | 2 | In distribution |
| POP-GWR120-PKG6 | Length 254 mm | 6 | In distribution |
| POP-OTG202 | In distribution | ||
| POP-OBL225 | Lumen/Inner Diameter 2.8 mm | In distribution | |
| POP-GWR128 | Length 229 mm | In distribution | |
| GIN-FCP100 | In distribution | ||
| POP-SLV135 | Lumen/Inner Diameter 2.8 mm | In distribution | |
| POP-FXG200 | In distribution | ||
| POP-OTG201 | In distribution | ||
| POP-SLV145 | Lumen/Inner Diameter 3.4 mm | In distribution | |
| POP-INE225-IC | In distribution | ||
| POP-OBL200 | Lumen/Inner Diameter 2.2 mm | In distribution | |
| POP-JSK200 | In distribution | ||
| POP-VBA150 | In distribution | ||
| POP-TRI103 | In distribution | ||
| POP-SFT200 | In distribution | ||
| POP-OTG200 | In distribution | ||
| POP-OBL250 | Lumen/Inner Diameter 3.4 mm | In distribution | |
| POP-HND200 | In distribution | ||
| POP-SFT250 | In distribution | ||
| POP-IME200-IC | In distribution | ||
| POP-OTG203 | In distribution | ||
| POP-SFT225 | In distribution | ||
| POP-TRI102 | In distribution | ||
| POP-TRI100 | In distribution | ||
| POP-CYE200-IC | In distribution | ||
| POP-AOH100 | In distribution | ||
| POP-IMP100-C | In distribution | ||
| POP-IME200-AH | In distribution | ||
| POP-GWR120 | Outer Diameter 2 mm | In distribution | |
| POP-VBI100 | In distribution | ||
| POP-CBK200 | In distribution | ||
| POP-TRI101 | In distribution | ||
| POP-INE225-AH | In distribution | ||
| POP-IMP100 | In distribution | ||
| POP-DRG100 | In distribution | ||
| POP-JSK225 | In distribution | ||
| POP-WGD100 | In distribution | ||
| POP-SLV127 | Lumen/Inner Diameter 2.3 mm | In distribution | |
| POP-JSK250 | In distribution | ||
| POP-CYE200-AH | In distribution | ||
| POP-CAP100 | In distribution | ||
| POP-GWR120-PKG2 | Length 254 mm | 2 | In distribution |
| POP-GWR128-PKG6 | Length 229 mm | 6 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Razek Equipamentos | Razek Equipamentos Ltda | 11,578 |
| Orthopedic Manual Surgical Instrument | Globus Medical, Inc. | 4,784 |
| Instrument | Howmedica Osteonics Corp | 4,539 |
| Orthopedic Manual Surgical Instrument | Ortho Development Corp. | 4,076 |
| Knee Instruments | Medacta International SA | 3,944 |
| Kyocera Medical Technologies, Inc. | Kyocera Medical Technologies, Inc. | 3,420 |
| Arthrex® | Arthrex, Inc. | 3,106 |
| Spine Instruments | Medacta International SA | 2,892 |
| Orthopedic Manual Surgical Instrument | Medtronic Sofamor Danek, Inc. | 2,766 |
| Hip Instruments | Medacta International SA | 1,904 |
| Medtronic Reusable Instruments | Medtronic Sofamor Danek, Inc. | 1,756 |
| ReLine | Nuvasive, Inc. | 1,208 |
Showing 12 of 9,501. All products under Orthopedic Manual Surgical Instrument
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-07-04 | Class II | Process control | During the assembly of the FRT250 cartridge assembly, an incorrect component was used. Specifically, the FRT240-HEX (2) was used instead of the FRT250-HEX. | 6 units | |
| 2020-04-03 | Class III | Nonconforming Material/Component | The lot number on the pediatric orthopedic implant driver instrument handle does not match the lot number on the label. | 3 units | 2020-11-20 |
| 2019-10-02 | Class II | Device Design | There is a potential for the screws to have become loosened during ultrasonic cleaning of the knobs and the screws may come out. | 31 devices | 2020-10-26 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.