Armeo
7 catalogue numbers from Spring Pediatric, listed by Hocoma AG, under System, Isokinetic Testing And Evaluation. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Guangdong (3), Zhejiang (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Mateside Medical Devices Technology Co., Ltd. | Ningbo | Zhejiang | Contract manufacturer | 21 |
| Fourier Intelligence Inc. | Shanghai | Shanghai | Private-label distributor | 6 |
| Shanghai Siyi Intelligent Technology Co., Ltd. | Shanghai | Shanghai | Manufacturer | 3 |
| Shanghai Zdroid Medical Technology Co., Ltd. | Shanghai | Shanghai | Manufacturer | 3 |
| Zhengzhou Angelexo Scientific Co., Ltd. | Zhengzhou | Henan | Manufacturer | 2 |
| Changsha Jinuo Intelligent Technology Co., Ltd. | Changsha | Hunan | Manufacturer | 1 |
| Guangzhou Yikang Medical Equipment Industrial Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 1 |
| Shenzhen Shengye Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 1 |
| Zhuhai Rehaconn Medical Co., Ltd. | Zhuhai | Guangdong | Specification developer | 1 |
Record
| Listed by | Hocoma AG |
|---|---|
| FDA product code | IKK |
| Device type | System, Isokinetic Testing And Evaluation |
| Device class | Class 2 |
| Regulation | 21 CFR 890.1925 |
| Premarket notification | Exempt |
| Record published | 2016-08-22 |
| Record revised | 2026-02-10 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Distribution end date | 2025-10-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Spring Pediatric | Withdrawn | |
| Power | Withdrawn | |
| Support Harness | Withdrawn | |
| Boom | Withdrawn | |
| Spring Pro | Withdrawn | |
| Power | Withdrawn | |
| Spring | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Harmony SHR™ | Harmonic Bionics, Inc. | 12 |
| RPM2 Rx | Medhab, LLC | 8 |
| Trexo Robotics | Trexo Robotics, Inc. | 8 |
| Lower extremity intelligent feedback training system for children | Guangzhou Yikang Medical Equipment Industrial Co., Ltd. | 6 |
| Steprite | Medhab, LLC | 6 |
| Upper and lower limb active and passive motion assessment training instrument | Guangzhou Yikang Medical Equipment Industrial Co., Ltd. | 4 |
| Fourier | Fourier Intelligence Inc. | 4 |
| Bioness Integrated System (BITS)2.0.5 | Bioness Medical, Inc. | 4 |
| Multi-joint isokinetic training and testing system | Guangzhou Yikang Medical Equipment Industrial Co., Ltd. | 3 |
| Actiware | Respironics Inc. | 3 |
| Burt | Barrett Technology, LLC | 2 |
| LifeGlov and Lifehub System | Bioliberty Ltd | 2 |
Showing 12 of 92. All products under System, Isokinetic Testing And Evaluation
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2020-06-08 | Class II | Device Design | The motor controller may fail, which can potentially lead to an error in functionality of the Body Weights Support Rope, which means that the rope can go up or down in an uncontrolled way. | 494 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.