C253A

Catalogue number C253A, listed by Fujifilm Corporation, Japan, under Transducer, Ultrasonic, Diagnostic. 44 manufacturers in China are registered for this product code.

Registry build 21.09.26
44manufacturers in China registered for this device type
1catalogue number
1510(k) clearance

Who Else Makes It

Concentrated in Guangdong (18), Jiangsu (10), Shanghai (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code ITX
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Xuzhou Yongkang Electronic Science Technology Co., Ltd. Xuzhou Jiangsu Contract manufacturer 13
Hony Medical Co., Ltd. Taishan Guangdong Contract manufacturer 10
Xian Friendship Medical Electronics Co., Ltd. Xi’An Shaanxi Contract manufacturer 10
Taijia Medical Electronics (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Showing 12 of 44. All 44 manufacturers in China registered for Transducer, Ultrasonic, Diagnostic

Record

Regulatory record for C253A
Listed by Fujifilm Corporation, Japan
FDA product code ITX
Device type Transducer, Ultrasonic, Diagnostic
Device class Class 2
Regulation 21 CFR 892.1570
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K181376
Record published 2024-01-22
Record revised 2025-05-21 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment temperature 10 to 40 °C; Handling environment humidity 30 to 75 % RH; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment temperature -10 to 50 °C; Storage environment humidity 10 to 90 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal

Catalogue Numbers

Catalogue numbers for C253A
Catalogue number Size Status
C253A In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
SonoScape Sonoscape Medical Corp. 302
Biopsy Starter Kit Civco Medical Instruments Co., Inc. 172
Sheathes Sheathing Technologies, Inc. 170
Needle Guide Civco Medical Instruments Co., Inc. 156
Sheathes3D Sheathing Technologies, Inc. 78
Ultrasound Probe Cover Biopsy Needle Guide Advance Medical Designs, Inc. 78
ultrasonic transducer Edan Instruments, Inc. 70
Unbranded Advance Medical Designs, Inc. 68
Reusable Biopsy Bracket Protek Medical Products, Inc. 60
Ultrasound Probe Cover Biopsy Needle Guide Kit Advance Medical Designs, Inc. 58
Biopsy Bracket Civco Medical Instruments Co., Inc. 56
Transducer Cover Civco Medical Instruments Co., Inc. 54

Showing 12 of 1,678. All products under Transducer, Ultrasonic, Diagnostic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261170 2026-08-12

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of C253A
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Fujifilm Healthcare Americas Corporation 510(k) number 2021-10-14 Class II Software design Diagnostic ultrasound system with the specified
software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display
the measurement results correctly with two cardiology measurement functions:
Mitral Regu
15 units
Fujifilm Healthcare Americas Corporation 510(k) number 2021-10-14 Class II Software design When the ultrasound system is used in combination with a Fujifilm (formally Hitachi) transducer, there is an error in the calculation formula of Effective Regurgitant Orifice Area (EROA) when you perform MR Flow combined with Left Ventricul 48 US

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer