OptiCross 35
Peripheral Imaging Catheter
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (10), Shanghai (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Hony Medical Co., Ltd. | Taishan | Guangdong | Contract manufacturer | 10 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Showing 12 of 44. All 44 manufacturers in China registered for Transducer, Ultrasonic, Diagnostic
Record
| Listed by | Boston Scientific Corporation, United States |
|---|---|
| FDA product code | ITX |
| Device type | Transducer, Ultrasonic, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1570 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2020-06-15 |
| Record revised | 2023-10-16 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, serial number |
| Sizes | Catheter gauge 8 Fr |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| H7493932800350 | Catheter Gauge 8 Fr | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| SonoScape | Sonoscape Medical Corp. | 302 |
| Biopsy Starter Kit | Civco Medical Instruments Co., Inc. | 172 |
| Sheathes | Sheathing Technologies, Inc. | 170 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 156 |
| Sheathes3D | Sheathing Technologies, Inc. | 78 |
| Ultrasound Probe Cover Biopsy Needle Guide | Advance Medical Designs, Inc. | 78 |
| ultrasonic transducer | Edan Instruments, Inc. | 70 |
| Unbranded | Advance Medical Designs, Inc. | 68 |
| Reusable Biopsy Bracket | Protek Medical Products, Inc. | 60 |
| Ultrasound Probe Cover Biopsy Needle Guide Kit | Advance Medical Designs, Inc. | 58 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 56 |
| Transducer Cover | Civco Medical Instruments Co., Inc. | 54 |
Showing 12 of 1,678. All products under Transducer, Ultrasonic, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K200733 | 2020-04-17 |
| K152403 | 2015-09-22 |
| K123424 | 2013-02-20 |
| K073623 | 2008-03-13 |
| K080272 | 2008-03-11 |
| K060947 | 2006-04-19 |
| K041818 | 2004-11-10 |
| K940108 | 1994-12-07 |
| K913890 | 1992-11-09 |
| K902245 | 1990-10-09 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Boston Scientific Corp., Marina Bay Cust. Fulfillment Center | UDI-DI | 2020-08-24 | Class II | Process control | Opticross 35 Peripheral Imaging Catheter is being recalled because the incremental telescoping length markings near the proximal end of the catheter shaft can flake off when the device is manipulated. No patient harm has been reported to da | 41 devices | 2024-04-05 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-01-06 | Class II | Equipment maintenance | Reports of physicians experiencing inability to pass a 0.035″ guidewire through the guidewire lumen and exit port at the (proximal) Y-manifold of the imaging catheter. | 1068 single units | 2014-10-29 |
| 2008-10-09 | Not classified | Labeling mix-ups | Product is mislabeled as having a shelf life of 3 years, where the actual shelf life is 1 year. | 1033 units | 2009-07-27 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.