Site~Rite 8 Ultrasound System
Site~Rite 8 Ultrasound System 20mm Pinpoint GT Linear Probe (Remanufactured)
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (10), Shanghai (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Hony Medical Co., Ltd. | Taishan | Guangdong | Contract manufacturer | 10 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Showing 12 of 44. All 44 manufacturers in China registered for Transducer, Ultrasonic, Diagnostic
Record
| Listed by | Bard Access Systems, Inc., United States |
|---|---|
| FDA product code | ITX |
| Device type | Transducer, Ultrasonic, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1570 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2018-01-15 |
| Record revised | 2025-07-31 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment temperature -18 to 40 °C; Special storage condition: Keep dry; Storage environment atmospheric pressure 70 to 106 KiloPascal; Storage environment humidity 5 to 95 % RH |
| Sizes | Length 20 to 32 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 9770601 | Length 32 mm | In distribution |
| 9770603 | Length 20 mm | In distribution |
| 9770602Y | In distribution | |
| SR8 USv2.0.1 | In distribution | |
| 9770602 | In distribution | |
| 9770601Y | In distribution | |
| 9770603R | In distribution | |
| 9770601X | In distribution | |
| 9770602X | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| SonoScape | Sonoscape Medical Corp. | 302 |
| Biopsy Starter Kit | Civco Medical Instruments Co., Inc. | 172 |
| Sheathes | Sheathing Technologies, Inc. | 170 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 156 |
| Sheathes3D | Sheathing Technologies, Inc. | 78 |
| Ultrasound Probe Cover Biopsy Needle Guide | Advance Medical Designs, Inc. | 78 |
| ultrasonic transducer | Edan Instruments, Inc. | 70 |
| Unbranded | Advance Medical Designs, Inc. | 68 |
| Reusable Biopsy Bracket | Protek Medical Products, Inc. | 60 |
| Ultrasound Probe Cover Biopsy Needle Guide Kit | Advance Medical Designs, Inc. | 58 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 56 |
| Transducer Cover | Civco Medical Instruments Co., Inc. | 54 |
Showing 12 of 1,678. All products under Transducer, Ultrasonic, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K042445 | 2004-10-19 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, and packaged in various kits may not be sterile. | 8,561 units | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, and packaged in various needle guide kits may not be sterile. | 27,721 units | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, may not be sterile. | 121 boxes | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, and packaged in various needle guide kits may not be sterile. | 34,619 units | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, may not be sterile. | 2360 units | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, and packaged in various needle guide kits may not be sterile. | 121,435 units | 2005-04-22 |
| 2004-11-03 | Not classified | Other | Conductivity gel pouches, labeled as sterile, and packaged in various needle guide kits may not be sterile. | 46,141 units | 2005-04-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.