Triple Transducer Connect
10 catalogue numbers from P16535-51R, listed by Fujifilm Sonosite,inc., United States, under Transducer, Ultrasonic, Diagnostic. 44 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (18), Jiangsu (10), Shanghai (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Hony Medical Co., Ltd. | Taishan | Guangdong | Contract manufacturer | 10 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Showing 12 of 44. All 44 manufacturers in China registered for Transducer, Ultrasonic, Diagnostic
Record
| Listed by | Fujifilm Sonosite,inc., United States |
|---|---|
| FDA product code | ITX |
| Device type | Transducer, Ultrasonic, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1570 |
| Establishment | Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K130173 |
| Record published | 2017-03-30 |
| Record revised | 2018-07-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Handling environment humidity 15 to 95 % RH; Handling environment temperature -35 to 65 °C; Storage environment temperature -35 to 65 °C; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment atmospheric pressure 50 to 106 KiloPascal; Storage environment humidity 15 to 95 % RH |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| P16535-51R | In distribution | |
| P32003-20 | In distribution | |
| P16535-51 | In distribution | |
| P30373-01 | In distribution | |
| P16871-51 | In distribution | |
| P15922-16R | In distribution | |
| P16535-04 | In distribution | |
| P32003-21 | In distribution | |
| P16535-52R | In distribution | |
| P16535-52 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| SonoScape | Sonoscape Medical Corp. | 302 |
| Biopsy Starter Kit | Civco Medical Instruments Co., Inc. | 172 |
| Sheathes | Sheathing Technologies, Inc. | 170 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 156 |
| Sheathes3D | Sheathing Technologies, Inc. | 78 |
| Ultrasound Probe Cover Biopsy Needle Guide | Advance Medical Designs, Inc. | 78 |
| ultrasonic transducer | Edan Instruments, Inc. | 70 |
| Unbranded | Advance Medical Designs, Inc. | 68 |
| Reusable Biopsy Bracket | Protek Medical Products, Inc. | 60 |
| Ultrasound Probe Cover Biopsy Needle Guide Kit | Advance Medical Designs, Inc. | 58 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 56 |
| Transducer Cover | Civco Medical Instruments Co., Inc. | 54 |
Showing 12 of 1,678. All products under Transducer, Ultrasonic, Diagnostic
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Fujifilm Sonosite,inc. | 510(k) number | 2013-09-11 | Class II | Error in labeling | FUJIFILM SonoSite Inc. remove P21x/5-1 Transducer because the firm discovered the Biopsy Bracket Sensor is not working as intended. | 10 units | 2013-12-11 |
| Fujifilm Sonosite,inc. | 510(k) number | 2011-07-18 | Not classified | Software design | This is a software anomaly. In some circumstances, if the Systolic/Diastolic (S/D) ratio value is interpreted directly from the display, the clinician could potentially use an incorrect value of the S/D ratio in his/her assessment. | 4236 units (US) and 4089 units (internationally) | 2012-09-14 |
| Fujifilm Sonosite,inc. | 510(k) number | 2010-05-27 | Not classified | Nonconforming Material/Component | PowerPark system has a potential for loss of power at the corresponding wall outlet and/or circuit due to poor alignment. | 26 | 2011-04-18 |
| Fujifilm Sonosite,inc. | 510(k) number | 2007-02-05 | Not classified | Other | Laparoscopic transducer exceeds the limits specified for radio-frequency emissions by up to 10db. | 6 Devices | 2007-06-01 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2005-12-12 | Not classified | Other | 22 gauge needle guides were intermixed with 21 gauge guides and labeled as 21 gauge needle guides. | 355 boxes/24 kits per box | 2006-07-31 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.