Voluson

BT12 Software Upgrade Kit for VS6

Registry build 21.09.26
44manufacturers in China registered for this device type
15catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (18), Jiangsu (10), Shanghai (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code ITX
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Xuzhou Yongkang Electronic Science Technology Co., Ltd. Xuzhou Jiangsu Contract manufacturer 13
Hony Medical Co., Ltd. Taishan Guangdong Contract manufacturer 10
Xian Friendship Medical Electronics Co., Ltd. Xi’An Shaanxi Contract manufacturer 10
Taijia Medical Electronics (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Showing 12 of 44. All 44 manufacturers in China registered for Transducer, Ultrasonic, Diagnostic

Record

Regulatory record for Voluson
Listed by GE Ultrasound Korea, Ltd., South Korea
FDA product code ITX
Device type Transducer, Ultrasonic, Diagnostic
Device class Class 2
Regulation 21 CFR 892.1570
Establishment Manufacturer
510(k) K250543
Record published 2025-06-04
Record revised 2020-02-12 (version 6)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number
Storage Storage environment temperature -10 to 50 °C; Storage environment humidity 10 to 90 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment temperature 18 to 30 °C; Storage environment humidity 30 to 80 % RH; Handling environment atmospheric pressure 70 to 106 KiloPascal
Distribution end date 2024-12-09

Catalogue Numbers

Catalogue numbers for Voluson
Catalogue number Size Status
Performance 18 In distribution
S8 BT18 In distribution
S8t BT22 In distribution
Performance 16 In distribution
S10 Expert BT18 In distribution
S10 Expert BT22 In distribution
P8 BT16 In distribution
Signature 20 In distribution
P6 BT18 In distribution
Signature 20 BT27 In distribution
SWIFT+ BT23 In distribution
S6 BT12 to BT14 UPG Withdrawn
S6 BT14 to BT15 UPG Withdrawn
S8 BT14 to BT15 UPG Withdrawn
S6 BT11 to BT12 UPG Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
SonoScape Sonoscape Medical Corp. 302
Biopsy Starter Kit Civco Medical Instruments Co., Inc. 172
Sheathes Sheathing Technologies, Inc. 170
Needle Guide Civco Medical Instruments Co., Inc. 156
Sheathes3D Sheathing Technologies, Inc. 78
Ultrasound Probe Cover Biopsy Needle Guide Advance Medical Designs, Inc. 78
ultrasonic transducer Edan Instruments, Inc. 70
Unbranded Advance Medical Designs, Inc. 68
Reusable Biopsy Bracket Protek Medical Products, Inc. 60
Ultrasound Probe Cover Biopsy Needle Guide Kit Advance Medical Designs, Inc. 58
Biopsy Bracket Civco Medical Instruments Co., Inc. 56
Transducer Cover Civco Medical Instruments Co., Inc. 54

Showing 12 of 1,678. All products under Transducer, Ultrasonic, Diagnostic

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Voluson
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Healthcare (China) Co., Ltd. UDI-DI 2025-01-31 Class II Software design For certain MR systems, a scan can be resumed following a Power Monitor trip when the “6-minute average SAR” is above the limit indicated on the “SAR Display”. The user interface may incorrectly enable a scan to proceed earlier than intende 2538
GE Medical Systems, LLC 510(k) number 2019-07-02 Class II Device Design Potential for a transducer mis-alignment in certain transvaginal probes. 2 devices 2020-10-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer