T-MAT G/RA Film
T-MAT G/RA Film TRPL 30X90cm 25SH
Who Else Makes It
Concentrated in Jiangsu (1), Shanghai (1), Fujian (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Rayco (Xiamen) Medical Products Company Limited | Xiamen | Fujian | Contract manufacturer | 1 |
| Zogear Medical Co., Ltd. | Yizheng | Jiangsu | Contract manufacturer | 75 |
| Shanghai Alwings Medical Instrument Co., Ltd. | Shanghai | Shanghai | Manufacturer | 39 |
Record
| Listed by | Carestream Health, Inc., United States |
|---|---|
| FDA product code | IWZ |
| Device type | Film, Radiographic |
| Device class | Class 1 |
| Regulation | 21 CFR 892.1840 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2016-09-16 |
| Record revised | 2018-11-15 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number |
| Storage | Handling environment temperature 4 to 25 °C; Storage environment humidity from 30 % RH; Storage environment temperature 4 to 25 °C; Handling environment humidity from 60 % RH |
| Packaging | Case of 5, case of 100 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 25 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 25 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 25 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution | |
| T-MAT G/RA Film | 100 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Gafchromic™ | Ashland Specialty Ingredients, G.P. | 151 |
| Dryview DVB Laser Imaging Film | Carestream Health, Inc. | 42 |
| Imaging Plates | Palodex Group OY | 24 |
| Henry Schein | Henry Schein, Inc. | 24 |
| Fuji Medical X-RAY Film | Fujifilm Corporation | 21 |
| Ultra-speed | Carestream Health, Inc. | 17 |
| Dryview DVM Mammography Laser Imaging Film | Carestream Health, Inc. | 16 |
| E Blue X-ray Film WB | Carestream Health, Inc. | 15 |
| Medical X-ray Green / MXG Film | Carestream Health, Inc. | 15 |
| Rad Control | Typenex Medical, LLC | 15 |
| Insight | Carestream Health, Inc. | 15 |
| Medical X-ray Blue / MXB Film | Carestream Health, Inc. | 15 |
Showing 12 of 259. All products under Film, Radiographic
Recalls
3 of these are Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-07-02 | Class III | Package design/selection | The Indicator Dot on the film packet’s outer printed paper labeling was incorrectly positioned relative to the location of the raised dot on the dental intraoral film. This may cause confusion for the dental practitioner. If the processed | 1633 boxes | 2016-05-25 |
| 2014-07-02 | Class III | Package design/selection | The Indicator Dot on the film packet’s outer printed paper labeling was incorrectly positioned relative to the location of the raised dot on the dental intraoral film. This may cause confusion for the dental practitioner. If the processed | 1633 boxes | 2016-05-25 |
| 2013-01-17 | Class III | Process change control | Missing symbols and manufacturing information on the clear carton label. The expiration dating symbol is missing but the expiration date is not missing. The Lot symbol is missing but the lot number is not missing. The Manufacturer symbol | 101 cartons: Domestic – 95 cartons; Foreign – 6 cartons | 2016-05-18 |
| 2011-12-20 | Not classified | Nonconforming Material/Component | Kodak DryView DVB Film is being recalled because it does not meet the specification for maximum density. | 24 cartridges | 2016-05-17 |
| 2010-03-12 | Not classified | Mixed-up of materials/components | Product mix-up. The firm received a customer complaint indicating that the customer had opened a box of film and although it was supposed to be T-MAT L/RA, it was performing like T-MAT G/RA. | 875 boxes | 2010-07-07 |
| 2010-03-12 | Not classified | Mixed-up of materials/components | Product mix-up. The firm received a customer complaint indicating that the customer had opened a box of film and although it was supposed to be T-MAT L/RA, it was performing like T-MAT G/RA. | 560 boxes | 2010-07-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.