Acuson X600 Diagnostic Ultrasound System

ACUSON X600 is a mobile diagnostic ultrasound system for imaging anatomical structures and fluid flow. It transmits ultrasound into the body and processes returning echoes for display on a…

Registry build 21.09.26

ACUSON X600 is a mobile diagnostic ultrasound system for imaging anatomical structures and fluid flow. It transmits ultrasound into the body and processes returning echoes for display on a flat-panel screen. Measurement tools and analysis packages provide information used in clinical diagnosis.

Imaging modes include B-mode, M-mode, pulsed-wave and continuous-wave Doppler, colour and amplitude Doppler, and tissue Doppler. The system also provides tissue-harmonic imaging, combined modes, and 3D and 4D imaging. Displayed thermal and mechanical indices relate to potential ultrasound bioeffects.

Clinical Applications

The X600 supports abdominal, renal, fetal, small-organ, cardiac, cerebrovascular and peripheral-vessel imaging. Other applications include pediatric, cephalic, transrectal, transvaginal, urological, orthopedic and musculoskeletal examinations, along with transesophageal and intracardiac imaging.

22manufacturers in China registered for this device type
1catalogue number
75510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (10), Jiangsu (5), Shandong (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYN
Manufacturer City Province Registered as Device types
Xuzhou Yongkang Electronic Science Technology Co., Ltd. Xuzhou Jiangsu Contract manufacturer 13
Xian Friendship Medical Electronics Co., Ltd. Xi’An Shaanxi Contract manufacturer 10
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Shenzhen Viatom Technology Co., Ltd. Shenzhen Guangdong Manufacturer 9
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Sonoscape Medical Corp. Shenzhen Guangdong Manufacturer 7
Carbon (Shenzhen) Medical Device Co., Ltd. Shenzhen Guangdong Manufacturer 6
Chison Medical Technologies Co., Ltd. Wuxi Jiangsu Contract manufacturer 5

Showing 12 of 22. All 22 manufacturers in China registered for System, Imaging, Pulsed Doppler, Ultrasonic

Record

Regulatory record for Acuson X600 Diagnostic Ultrasound System
Listed by Siemens Medical Solutions USA, Inc., United States
FDA product code IYN
Device type System, Imaging, Pulsed Doppler, Ultrasonic
Device class Class 2
Regulation 21 CFR 892.1550
Establishment Contract manufacturer, Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer
510(k) K141846
Record published 2016-09-24
Record revised 2021-11-18 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number

Catalogue Numbers

Catalogue numbers for Acuson X600 Diagnostic Ultrasound System
Catalogue number Size Status
10789636 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Hisense Qingdao Hisense Medical Co., Ltd. 219
Medisono Medisono, LLC 173
SonoScape Sonoscape Medical Corp. 111
Hisense Qingdao Hisense Medical Equipment Co., Ltd. 92
Diagnostic Ultrasound System Shenzhen Mindray BIO-Medical Electronics Co., Ltd. 89
Medistim Interconnect Cable Medistim ASA 40
Compact Cart Philips Ultrasound LLC 30
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
Clarius Ultrasound Scanner Clarius Mobile Health Corp. 25
Logiq GE Ultrasound Korea, Ltd. 25
Wisonic Shenzhen Wisonic Medical Technology Co., Ltd. 22
Vivid GE Vingmed Ultrasound A/S 21

Showing 12 of 934. All products under System, Imaging, Pulsed Doppler, Ultrasonic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260844 2026-06-16
K253487 2025-11-17
K253457 2025-11-13
K251481 2025-08-20
K242523 2024-11-19
K243299 2024-11-15
K240704 2024-07-22
K233610 2024-06-12
K232145 2023-10-30
K232617 2023-09-26
K230207 2023-02-13
K223735 2023-02-06
K221190 2022-08-16
K221500 2022-06-14
K213487 2022-02-11
K211859 2021-07-20
K210743 2021-04-01
K202683 2020-10-15
K201462 2020-06-24
K201130 2020-05-26
K200585 2020-04-22
K200707 2020-04-15
K200644 2020-04-10
K193257 2020-01-31
K192835 2019-10-22
K191922 2019-08-15
K181098 2018-05-31
K180067 2018-02-07
K173957 2018-02-01
K180039 2018-02-01
K172374 2017-08-15
K163396 2017-01-04
K161787 2016-07-28
K150050 2015-02-09
K142876 2014-10-23
K141846 2014-08-07
K140959 2014-04-30
K131164 2013-12-24
K130881 2013-10-11
K130739 2013-06-06
K130619 2013-03-21
K123622 2012-12-05
K123001 2012-10-26
K122825 2012-09-28
K121699 2012-06-22
K111674 2011-06-30
K102017 2010-09-20
K093812 2010-03-03
K083114 2009-03-31
K070576 2007-03-26
K063761 2007-01-04
K063138 2006-11-22
K061980 2006-08-17
K061946 2006-07-21
K052894 2005-11-23
K052331 2005-11-10
K052410 2005-09-22
K051139 2005-05-13
K050240 2005-02-15
K050034 2005-01-13
K043016 2004-11-16
K042770 2004-10-20
K042055 2004-08-16
K042044 2004-08-13
K041319 2004-06-07
K040060 2004-01-28
K033196 2003-10-16
K032114 2003-07-21
K032111 2003-07-18
K023720 2002-11-20
K003125 2000-10-20
K001400 2000-08-01
K980557 1998-04-24
K945072 1995-11-21
K945773 1995-08-07

Recalls

39 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-08-15 Class II Software design If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliter 1990
2024-08-15 Class II Software design If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliter 7022
2024-08-15 Class II Software design If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliter 321
2024-02-23 Class II Software design On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will 67
2024-02-23 Class II Software design On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will 628
2024-02-23 Class II Software design On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will 5090
2023-07-13 Class II Software design If a user-generated preset for an 18L6 transducer created on a 1.0 ultrasound system is used with a 2.0 ultrasound system, the 2.0 ultrasound system will display underestimated measurement results when using an 18L6 transducer and viewing i 796
2022-03-07 Class II Process control Transducers (component of ultrasound system) may exceed recommended thermal index limits 31 units
2022-01-19 Class II Software design The clip store function in the ultrasound imaging system does not work when the system has a disk full error. This could cause a delay in treatment if the ultrasound system is unable to save clips as study documentation during a high risk 2846
2021-11-12 Class II Software design Due to a calculation error in the measurement when using 2D trace (manual trace) tool. The trace circumference value is overestimated and may potentially result in misdiagnosis of a patient’s condition. 1161 systems
2021-07-12 Class II Software change control Due to intermittent failures of the power supply in the ultrasound system which renders it inoperable. 15 systems 2024-10-16
2021-02-04 Class II Software Design Change The ultrasound system averages the Mean Sac Diameter (MSD) and Gestational Sac Diameter (GSD) into the Estimated Date of Delivery (EDD) calculation. This may result in an incorrect EDD, which may influence patient management decisions regar 1,172 systems
2019-01-28 Class II Software design The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined. The transit voltage values based on PW Doppler are calculated normally but not l 70 systems
2019-01-28 Class II Software design The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined. The transit voltage values based on PW Doppler are calculated normally but not l 1869 systems
2019-01-28 Class II Software design The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined. The transit voltage values based on PW Doppler are calculated normally but not l 2262 systems
2019-01-28 Class II Software design The action is being initiated due to internal testing which identified a possibility for transducers to exceed the acoustic output power (AOP) values defined. The transit voltage values based on PW Doppler are calculated normally but not l 1384 systems
2018-03-05 Class II Device Design The ECG signal may flatline due to electromagnetic interference during the use of electrosurgical equipment. 229 systems 2021-02-26
2018-01-26 Class II Under Investigation by firm The application may underestimate the EROA (Effective Regurgitant Orifice Area) in comparison to the same patient results obtained with the 4Z1c volume transthoracic echocardiography transducer. 564 systems 2020-07-02
2017-03-30 Class II Software design When scanning with the 18L6 HD transducer on the ACUSON HELX” Evolution with Touch Control, the ultrasound system may display a triple image or an image with a dark band. For the triple image issue, the system repeats one-third of the apert 2,045 systems 2019-03-21
2016-11-07 Class II Device Design Firm received reports about “acquisition errors” and the deterioration of material covering the articulating section of the Z6Ms transesophageal transducer. 33 2017-05-26
2016-04-08 Class II Software design While imaging with a transesophageal (TEE) transducer (Z6Ms, V5Ms, or V7M), user may lose the ability to control the color region of interest, the pulsed wave or continuous wave Doppler gate or cursor, the M-mode cursor, the 2D field of vie 87 2017-01-18
2015-10-07 Class II Device Design Siemens will provide all customers a new version of system software (VA35E or VB10C depending on the hardware configuration). Hardware fixes will be implemented to address situations where the metal component used to engage the wheel lock 2,099 units 2017-10-19
2015-09-05 Class II Software design Due to a communication error between the software and V5Ms transducers rotation function, ACUSON X700 ultrasound systems at software versions 1.1.04, display an IMG_15 error message causes the system to lock up, which requires a reboot to r 4 2016-04-27
2015-08-19 Class II Software design The ACUSON SC2000 ultrasound system considers uppercase/lowercase differences in the same patient name as unique patient instances when registered on the same ultrasound system.
If these differences are not corrected at the time of registr
2039 devices 2017-10-19
2015-06-29 Class II Under Investigation by firm When using the CIVCO biopsy attachments in combination with the ACUSON S Family on-screen guidelines, the biopsy needle may traverse outside the on-screen
guidelines.
4140 total 2018-01-18
2015-06-25 Class II Software Design Change Potential measurement error on ACUSON S Family ultrasound system. When repositioning the Virtual Touch IQ region of interest from the original (default) location, the lateral position of the measurement tool may not align with the lateral p 629 units 2017-10-19
2015-06-25 Class II Device Design Potential measurement error on ACUSON S Family ultrasound system when using the Doppler manual trace measurement tool in full screen format that has a low probability of misdiagnosis. 1789 units 2017-10-19
2015-05-29 Class II Software design When performing a 2D Stress Echo study, some following keystrokes result in a potential loss of data, where some selected clips may not be saved as part of the study. 573 devices 2017-03-09
2015-01-12 Class II Component design/selection The bolt holding the control panel of the ACUSON SC2000 in a fixed position may fail and the Control panel cannot be locked into position. 230 2015-11-12
2014-06-03 Class II Software design There is a potential measurement error with the Auto-Stats (auto statistics) measurement tool on the ACUSON S Family ultrasound system. 790 units 2016-05-25
2014-04-23 Class II Software design Software issues with ACUSON SC2000 ultrasound with software version 3/5 (VA35) – may incorrectly display the color flow data in the wrong position and when Doppler Frequency is adjusted, the system does not restart the pulsed wave Doppler 257 units 2015-11-12
2014-04-23 Class II Software design Potential malfunction due to a software issue for ACUSON SC2000 ultrasound systems using software version 3.5 (VA35) when using the stress echo feature which could cause the need for the study to be repeated. 177 units 2015-11-12
2014-04-02 Class II Software Design Change When fourSight 4D ultrasound imaging, 3-Scrape real time 3D imaging, or Anatomical M-mode are used during an Obstetric or Gynecology study, data from the previous patient could replace the current patient’s date in the report. 490 2015-11-12
2014-03-07 Class II Device Design ACUSON P300 ultrasound systems using the PA230 transducer with a user-defined preset which includes the 100% setting for output power could cause the transducer surface temperature to exceed the maximum allowable limit. 675 2015-11-12
2013-12-22 Class II Nonconforming Material/Component The user interface assembly on the ACUSON SC2000 may become loose with the potential for the entire module to fall off of the ultrasound system. 843 active units 2015-05-06
2013-12-22 Class II Device Design The locking mechanism that is intended to hold the control panel in a fixed position can become loose and fail to lock the rotation of the control panel, making it unable to steer or control during transport. 271 units 2015-03-05
2013-07-10 Class II Device Design Software issue results in inaccurate 3D image may result in ablation in wrong location. 26 units 2013-11-25
2013-03-28 Class II Device Design When using the V5M transducer, the display of the temperature on the ACUSON SC2000 system can be lower than the actual temperature of the V5M transducer. This occurs only if the system hardware contains revision 4 of the MPI Board. There is 120 units 2014-02-14
2012-07-11 Class II Other In certain situations, loss of post exercise images can occur in Stress Echo. 476 2015-05-06
2012-04-25 Not classified Software design When using the Advanced SieClear spatial compounding feature a synchronization error may occur which can cause a mismatch between the image and the depth scale. 45 2012-10-19

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P940005 1996-04-11 ULTRAMARK 9 HIGH DEFINITION IMAGING UULTRASOUND SYSTEM Advanced Technology Laboratories, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer