Hitachi
Diagnostic Ultrasound System wireless
Who Else Makes It
Concentrated in Guangdong (10), Jiangsu (5), Shandong (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Shenzhen Viatom Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 9 |
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| Sonoscape Medical Corp. | Shenzhen | Guangdong | Manufacturer | 7 |
| Carbon (Shenzhen) Medical Device Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 22. All 22 manufacturers in China registered for System, Imaging, Pulsed Doppler, Ultrasonic
Record
| Listed by | Hitachi, Ltd., United States |
|---|---|
| FDA product code | IYN |
| Device type | System, Imaging, Pulsed Doppler, Ultrasonic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1550 |
| 510(k) | K163505 |
| Record published | 2018-07-03 |
| Record revised | 2021-07-02 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Hydrogen Peroxide |
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment temperature 14 to 122 °C; Storage environment humidity 10 to 90 % RH; Handling environment temperature 50 to 104 °F; Handling environment humidity 30 to 75 % RH |
| Distribution end date | 2021-06-30 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ARIETTA precision | Withdrawn | |
| Prosound Alpha 6 | Withdrawn | |
| UST-9150 | Withdrawn | |
| S11 | Withdrawn | |
| C253 | Withdrawn | |
| F37 | Withdrawn | |
| ARIETTA 60 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hisense | Qingdao Hisense Medical Co., Ltd. | 219 |
| Medisono | Medisono, LLC | 173 |
| SonoScape | Sonoscape Medical Corp. | 111 |
| Hisense | Qingdao Hisense Medical Equipment Co., Ltd. | 92 |
| Diagnostic Ultrasound System | Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | 89 |
| Medistim Interconnect Cable | Medistim ASA | 40 |
| Compact Cart | Philips Ultrasound LLC | 30 |
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 27 |
| Clarius Ultrasound Scanner | Clarius Mobile Health Corp. | 25 |
| Logiq | GE Ultrasound Korea, Ltd. | 25 |
| Wisonic | Shenzhen Wisonic Medical Technology Co., Ltd. | 22 |
| Vivid | GE Vingmed Ultrasound A/S | 21 |
Showing 12 of 934. All products under System, Imaging, Pulsed Doppler, Ultrasonic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K163505 | 2017-05-30 |
| K162902 | 2016-12-15 |
| K162583 | 2016-11-17 |
| K160559 | 2016-10-18 |
| K061608 | 2006-11-22 |
| K053258 | 2005-12-09 |
| K013722 | 2002-02-11 |
| K012239 | 2001-08-10 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Fujifilm Healthcare Americas Corporation | 510(k) number | 2021-10-14 | Class II | Software design | When the ultrasound system is used in combination with a Fujifilm (formally Hitachi) transducer, there is an error in the calculation formula of Effective Regurgitant Orifice Area (EROA) when you perform MR Flow combined with Left Ventricul | 48 US |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P940005 | 1996-04-11 | ULTRAMARK 9 HIGH DEFINITION IMAGING UULTRASOUND SYSTEM | Advanced Technology Laboratories, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.