NovaBot Automated Headset
NovaBot Automated Headset accessory for the Lucid TCD. When connected to the Lucid TCD, the combined device is referred to as the NovaGuide. The NovaBot is a cart mounted, robotic…
NovaBot Automated Headset accessory for the Lucid TCD. When connected to the Lucid TCD, the combined device is referred to as the NovaGuide. The NovaBot is a cart mounted, robotic transcranial Doppler (TCD) probe positioning accessory for the previously cleared Lucid TCD (K160442) which assists the user in the acquisition of cerebral blood flow velocity (CBFV) and the occurrence of transient emboli within the blood stream, via the patient’s temporal acoustic windows.
Who Else Makes It
Concentrated in Guangdong (10), Jiangsu (5), Shandong (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Shenzhen Viatom Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 9 |
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| Sonoscape Medical Corp. | Shenzhen | Guangdong | Manufacturer | 7 |
| Carbon (Shenzhen) Medical Device Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 6 |
| Chison Medical Technologies Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 5 |
Showing 12 of 22. All 22 manufacturers in China registered for System, Imaging, Pulsed Doppler, Ultrasonic
Record
| Listed by | Novasignal Corporation, United States |
|---|---|
| FDA product code | IYN |
| Device type | System, Imaging, Pulsed Doppler, Ultrasonic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1550 |
| 510(k) | K180455 |
| Record published | 2020-08-31 |
| Record revised | 2022-08-19 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NA-RBT1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hisense | Qingdao Hisense Medical Co., Ltd. | 219 |
| Medisono | Medisono, LLC | 173 |
| SonoScape | Sonoscape Medical Corp. | 111 |
| Hisense | Qingdao Hisense Medical Equipment Co., Ltd. | 92 |
| Diagnostic Ultrasound System | Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | 89 |
| Medistim Interconnect Cable | Medistim ASA | 40 |
| Compact Cart | Philips Ultrasound LLC | 30 |
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 27 |
| Clarius Ultrasound Scanner | Clarius Mobile Health Corp. | 25 |
| Logiq | GE Ultrasound Korea, Ltd. | 25 |
| Wisonic | Shenzhen Wisonic Medical Technology Co., Ltd. | 22 |
| Vivid | GE Vingmed Ultrasound A/S | 21 |
Showing 12 of 934. All products under System, Imaging, Pulsed Doppler, Ultrasonic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K213279 | 2022-03-02 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| NeuraSignal, Inc. | 510(k) number | 2022-12-16 | Class II | Nonconforming Material/Component | Transcranial Doppler/ultrasound system tablet has a faulty hard drive, which will cause the system to freeze and reboot. Initially, the system will reboot to a normal operable state but eventually the system will be rendered inoperable. | 4 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P940005 | 1996-04-11 | ULTRAMARK 9 HIGH DEFINITION IMAGING UULTRASOUND SYSTEM | Advanced Technology Laboratories, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.