Avvigo™ Guidance System II

5 catalogue numbers from H749009765R0, listed by Boston Scientific Corporation, United States, under System, Imaging, Pulsed Echo, Ultrasonic. 37 manufacturers in China are registered for this product code.

Registry build 21.09.26
37manufacturers in China registered for this device type
5catalogue numbers in this listing
7510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Guangdong (14), Jiangsu (9), Shanghai (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYO
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Raise Medical Industries, Inc. Foshan Guangdong Contract manufacturer 16
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Xuzhou Yongkang Electronic Science Technology Co., Ltd. Xuzhou Jiangsu Contract manufacturer 13
Taijia Medical Electronics (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Taizhou City K&W International Trade Co., Ltd. Jiangyan Jiangsu Repacker / relabeller 38
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Showing 12 of 37. All 37 manufacturers in China registered for System, Imaging, Pulsed Echo, Ultrasonic

Record

Regulatory record for Avvigo™ Guidance System II
Listed by Boston Scientific Corporation, United States
FDA product code IYO
Device type System, Imaging, Pulsed Echo, Ultrasonic
Device class Class 2
Regulation 21 CFR 892.1560
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2021-11-17

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Avvigo™ Guidance System II
Catalogue number Size Status
H749009765R0 In distribution
H749009881IZ0 In distribution
H749009881CD0 In distribution
H749009881CZ0 In distribution
H7490097650 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Hitachi Hitachi, Ltd. 224
eTRAX™ Needle Civco Medical Instruments Co., Inc. 43
BladderScan® Verathon Inc. 38
Verza Guidance System Civco Medical Instruments Co., Inc. 37
Needle Guide Civco Medical Instruments Co., Inc. 34
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 34
Biopsy Bracket Civco Medical Instruments Co., Inc. 33
Tracking Bracket Starter Kit Civco Medical Instruments Co., Inc. 29
System, Imaging, Pulsed Echo, Ultrasonic GE Healthcare Japan Corporation 23
eTRAX™ Needle System Starter Kit Civco Medical Instruments Co., Inc. 20
Tracking Bracket Civco Medical Instruments Co., Inc. 19
Logiq GE Ultrasound Korea, Ltd. 18

Showing 12 of 805. All products under System, Imaging, Pulsed Echo, Ultrasonic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K152316 2015-09-18
K130243 2013-03-01
K123535 2013-01-15
K072517 2007-09-26
K982840 1998-11-09
K980851 1998-04-22
K890772 1989-05-10

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2008-09-05 Not classified Process control Computer malware: Products may be infected with a worm (computer malware) which could infect a computer network to which it may be connected. 357 units 2009-05-18
2000-04-11 Not classified Process control Improperly terminated wires on a component of the iLab Acquisition processor power supply could cause the processor to lock-up or stop, and prolong the patients procedure. 120 units 2009-04-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer