Master-Vu B-Scan Ophthalmic Ultrasound System
The Master-Vu B-Scan Ophthalmic Ultrasound System is a non-invasive, active, diagnostic and biometric device intended for use in ophthalmic applications by imaging the internal structures…
The Master-Vu B-Scan Ophthalmic Ultrasound System is a non-invasive, active, diagnostic and biometric device intended for use in ophthalmic applications by imaging the internal structures of the eye. They system consists of a sealed, posterior segment B-probe and cable designed to interface with any standard personal computer (host PC). The probe utilizes a 12 MHz transducer with a sector scanning probe operating on the host PC. The software for the Master-Vu B-Scan allows the host PC to function as the main control interface and display for the B-scan system. The system is provided with the portable, hand-held B-probe with 12 MHz transducer, USB cable, Master-Vu B software on a flash drive, carry case and user manual.
Who Else Makes It
Concentrated in Guangdong (14), Jiangsu (9), Shanghai (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Raise Medical Industries, Inc. | Foshan | Guangdong | Contract manufacturer | 16 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Taizhou City K&W International Trade Co., Ltd. | Jiangyan | Jiangsu | Repacker / relabeller | 38 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Sterigenics Shanghai E Beam Ltd. | Shanghai | Shanghai | Contract manufacturer | 14 |
Showing 12 of 37. All 37 manufacturers in China registered for System, Imaging, Pulsed Echo, Ultrasonic
Record
| Listed by | Sonomed, Inc., United States |
|---|---|
| FDA product code | IYO |
| Device type | System, Imaging, Pulsed Echo, Ultrasonic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1560 |
| Establishment | Manufacturer |
| 510(k) | K073196 |
| Record published | 2016-08-10 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MV5600 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hitachi | Hitachi, Ltd. | 224 |
| eTRAX™ Needle | Civco Medical Instruments Co., Inc. | 43 |
| BladderScan® | Verathon Inc. | 38 |
| Verza Guidance System | Civco Medical Instruments Co., Inc. | 37 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 34 |
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 34 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 33 |
| Tracking Bracket Starter Kit | Civco Medical Instruments Co., Inc. | 29 |
| System, Imaging, Pulsed Echo, Ultrasonic | GE Healthcare Japan Corporation | 23 |
| eTRAX™ Needle System Starter Kit | Civco Medical Instruments Co., Inc. | 20 |
| Tracking Bracket | Civco Medical Instruments Co., Inc. | 19 |
| Logiq | GE Ultrasound Korea, Ltd. | 18 |
Showing 12 of 805. All products under System, Imaging, Pulsed Echo, Ultrasonic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K140199 | 2014-04-01 |
| K100252 | 2010-04-09 |
| K073196 | 2007-12-19 |
| K060626 | 2006-04-11 |
| K040668 | 2004-04-13 |
| K931908 | 1994-09-29 |
| K931909 | 1994-09-29 |
| K924311 | 1992-12-08 |
| K883917 | 1989-03-31 |
| K843696 | 1985-02-26 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.