MDU5 Plus
Catalogue number H749MDU5PLUSFH0, listed by Boston Scientific Corporation, United States, under System, Imaging, Pulsed Echo, Ultrasonic. 37 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (14), Jiangsu (9), Shanghai (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Raise Medical Industries, Inc. | Foshan | Guangdong | Contract manufacturer | 16 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Taizhou City K&W International Trade Co., Ltd. | Jiangyan | Jiangsu | Repacker / relabeller | 38 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Sterigenics Shanghai E Beam Ltd. | Shanghai | Shanghai | Contract manufacturer | 14 |
Showing 12 of 37. All 37 manufacturers in China registered for System, Imaging, Pulsed Echo, Ultrasonic
Record
| Listed by | Boston Scientific Corporation, United States |
|---|---|
| FDA product code | IYO |
| Device type | System, Imaging, Pulsed Echo, Ultrasonic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1560 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2021-11-29 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| H749MDU5PLUSFH0 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hitachi | Hitachi, Ltd. | 224 |
| eTRAX™ Needle | Civco Medical Instruments Co., Inc. | 43 |
| BladderScan® | Verathon Inc. | 38 |
| Verza Guidance System | Civco Medical Instruments Co., Inc. | 37 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 34 |
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 34 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 33 |
| Tracking Bracket Starter Kit | Civco Medical Instruments Co., Inc. | 29 |
| System, Imaging, Pulsed Echo, Ultrasonic | GE Healthcare Japan Corporation | 23 |
| eTRAX™ Needle System Starter Kit | Civco Medical Instruments Co., Inc. | 20 |
| Tracking Bracket | Civco Medical Instruments Co., Inc. | 19 |
| Logiq | GE Ultrasound Korea, Ltd. | 18 |
Showing 12 of 805. All products under System, Imaging, Pulsed Echo, Ultrasonic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K152316 | 2015-09-18 |
| K130243 | 2013-03-01 |
| K123535 | 2013-01-15 |
| K072517 | 2007-09-26 |
| K982840 | 1998-11-09 |
| K980851 | 1998-04-22 |
| K890772 | 1989-05-10 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-09-05 | Not classified | Process control | Computer malware: Products may be infected with a worm (computer malware) which could infect a computer network to which it may be connected. | 357 units | 2009-05-18 |
| 2000-04-11 | Not classified | Process control | Improperly terminated wires on a component of the iLab Acquisition processor power supply could cause the processor to lock-up or stop, and prolong the patients procedure. | 120 units | 2009-04-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.