S31KP

Catalogue number S31KP, listed by Fujifilm Corporation, Japan, under System, Imaging, Pulsed Echo, Ultrasonic. 37 manufacturers in China are registered for this product code.

Registry build 21.09.26
37manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Guangdong (14), Jiangsu (9), Shanghai (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYO
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Raise Medical Industries, Inc. Foshan Guangdong Contract manufacturer 16
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Xuzhou Yongkang Electronic Science Technology Co., Ltd. Xuzhou Jiangsu Contract manufacturer 13
Taijia Medical Electronics (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Philips Ultrasound (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Taizhou City K&W International Trade Co., Ltd. Jiangyan Jiangsu Repacker / relabeller 38
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Sterigenics Shanghai E Beam Ltd. Shanghai Shanghai Contract manufacturer 14

Showing 12 of 37. All 37 manufacturers in China registered for System, Imaging, Pulsed Echo, Ultrasonic

Record

Regulatory record for S31KP
Listed by Fujifilm Corporation, Japan
FDA product code IYO
Device type System, Imaging, Pulsed Echo, Ultrasonic
Device class Class 2
Regulation 21 CFR 892.1560
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K134016
Record published 2021-07-18
Record revised 2025-05-12 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Liquid Chemical, Peracetic Acid, Hydrogen Peroxide, Ethylene Oxide, High-level Disinfectant
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -10 to 50 °C; Storage environment humidity 10 to 90 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment temperature 10 to 40 °C; Handling environment humidity 30 to 75 % RH; Handling environment atmospheric pressure 70 to 106 KiloPascal

Catalogue Numbers

Catalogue numbers for S31KP
Catalogue number Size Status
S31KP In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Hitachi Hitachi, Ltd. 224
eTRAX™ Needle Civco Medical Instruments Co., Inc. 43
BladderScan® Verathon Inc. 38
Verza Guidance System Civco Medical Instruments Co., Inc. 37
Needle Guide Civco Medical Instruments Co., Inc. 34
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 34
Biopsy Bracket Civco Medical Instruments Co., Inc. 33
Tracking Bracket Starter Kit Civco Medical Instruments Co., Inc. 29
System, Imaging, Pulsed Echo, Ultrasonic GE Healthcare Japan Corporation 23
eTRAX™ Needle System Starter Kit Civco Medical Instruments Co., Inc. 20
Tracking Bracket Civco Medical Instruments Co., Inc. 19
Logiq GE Ultrasound Korea, Ltd. 18

Showing 12 of 805. All products under System, Imaging, Pulsed Echo, Ultrasonic

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of S31KP
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Fujifilm Healthcare Americas Corporation 510(k) number 2024-04-11 Class II Device Design AC adapters of Noblus can heat up, and cause smoke in the worst case, when an excessive mechanical stress is applied to the socket for power cable (frequent insertion/removal of the power cable). 418 units
Fujifilm Healthcare Americas Corporation 510(k) number 2021-10-14 Class II Software design Diagnostic ultrasound system with the specified
software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display
the measurement results correctly with two cardiology measurement functions:
Mitral Regu
15 units
Fujifilm Healthcare Americas Corporation 510(k) number 2020-01-31 Class II Process change control These 18 probes may have mis-wiring in the inner cables, causing decreased sensitivity and thus resulting in lower peak velocity readings. 18 2020-07-31
Fujifilm Healthcare Americas Corporation 510(k) number 2017-05-02 Class II Device Design The strength of the arm mounting mechanism was insufficient and had to be redesigned. 77 2018-11-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer