| 2022-01-24 | Class III | Error in labeling | Multi-Modality Touch Screen Modules (MM-TSM), which are bedside/secondary control units, used as part of Mobile IVUS systems, are missing the following labeling information: Unique Device Identifier, Legal Manufacturer Information, Part Num | 47 | |
| 2018-11-07 | Class II | Employee error | Interoperability issue that affects certain systems that use the recalled software when it is connected to specific Hemodynamic Systems (HMS). | 3,667 units with software | 2022-07-14 |
| 2018-03-22 | Class II | Other | The incorrect resistor has been used in affected CORE M2 Imaging Systems, which causes noise and results in an overly bright IVUS Image. | 8 devices | 2021-04-28 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | Total of 4007 devices, all models | 2017-04-14 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | A total of 4007 devices, all models | 2017-04-14 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | A total of 4007 devices, all models | 2017-04-14 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | A total of 4007 devices, all models | 2017-04-14 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | A total of 4007 devices, all models | 2017-04-14 |
| 2015-06-22 | Class II | Software design | A software issue was discovered where an inaccurate FFR/iFR value could be calculated under certain circumstances. | A total of 4007 devices, all models | 2017-04-14 |
| 2013-09-23 | Class II | Nonconforming Material/Component | A limitation in interoperability between the Philips Xper Flex Cardia Physiomonitoring System and Volcano’s sS/Si, Core, and ComboMap systems. This limitation may impact the calculation of Fraction Flow Reserve (FFR) within the Volcano Syst | 227 total units – all models | 2015-07-09 |
| 2013-09-23 | Class II | Nonconforming Material/Component | A limitation in interoperability between the Philips Xper Flex Cardia Physiomonitoring System and Volcano’s sS/Si, Core, and ComboMap systems. This limitation may impact the calculation of Fraction Flow Reserve (FFR) within the Volcano Syst | 227 total units affected by the issue – all models | 2015-07-09 |
| 2013-09-23 | Class II | Nonconforming Material/Component | A limitation in interoperability between the Philips Xper Flex Cardia Physiomonitoring System and Volcano’s sS/Si, Core, and ComboMap systems. This limitation may impact the calculation of Fraction Flow Reserve (FFR) within the Volcano Syst | 227 total units – all models | 2015-07-09 |
| 2012-08-24 | Class II | Software design | The display on the system has the potential to change. In house testing eventually identified the unique sequence of events that must occur in order for this issue to manifest itself. | 1020 units | 2014-11-25 |
| 2010-06-29 | Not classified | Software design | Software defect results in improper image brightness, which may result in introduction of artifacts, which may cause misclassification of results and affect classification of tissue types. This may result in misdiagnosis and inappropriate t | 79 software kits | 2010-12-22 |
| 2010-06-11 | Not classified | Software design (manufacturing process) | Internal review of validation of pcMF Software kit found that instructions directs user to remove the rear panel, causing the potential for electric shock. | 8 units | 2012-02-07 |
| 2007-04-02 | Not classified | Other | During emissions testing, it was discovered that the product exceeds emissions limits for electromagnetic compatibility. | 351 units worldwide | 2008-06-03 |