System, Imaging, Pulsed Echo, Ultrasonic
E8CS
Who Else Makes It
Concentrated in Guangdong (14), Jiangsu (9), Shanghai (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Raise Medical Industries, Inc. | Foshan | Guangdong | Contract manufacturer | 16 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Xuzhou Yongkang Electronic Science Technology Co., Ltd. | Xuzhou | Jiangsu | Contract manufacturer | 13 |
| Taijia Medical Electronics (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Philips Ultrasound (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Taizhou City K&W International Trade Co., Ltd. | Jiangyan | Jiangsu | Repacker / relabeller | 38 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Sterigenics Shanghai E Beam Ltd. | Shanghai | Shanghai | Contract manufacturer | 14 |
Showing 12 of 37. All 37 manufacturers in China registered for System, Imaging, Pulsed Echo, Ultrasonic
Record
| Listed by | Parallel Design SAS, France |
|---|---|
| FDA product code | IYO |
| Device type | System, Imaging, Pulsed Echo, Ultrasonic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1560 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K161706 |
| Record published | 2016-10-06 |
| Record revised | 2020-06-03 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 10 to 95 % RH; Handling environment temperature -40 to 70 °C; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment atmospheric pressure 70 to 106 KiloPascal; Storage environment temperature -40 to 70 °C; Handling environment humidity 10 to 95 % RH |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| M5Sc-RS | In distribution | |
| 3Sc-RS | In distribution | |
| E8CS | In distribution | |
| 12S-D | In distribution | |
| L3-12-RS | In distribution | |
| 6S-RS | In distribution | |
| 6S-D | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Hitachi | Hitachi, Ltd. | 224 |
| eTRAX™ Needle | Civco Medical Instruments Co., Inc. | 43 |
| BladderScan® | Verathon Inc. | 38 |
| Verza Guidance System | Civco Medical Instruments Co., Inc. | 37 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 34 |
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 34 |
| Biopsy Bracket | Civco Medical Instruments Co., Inc. | 33 |
| Tracking Bracket Starter Kit | Civco Medical Instruments Co., Inc. | 29 |
| System, Imaging, Pulsed Echo, Ultrasonic | GE Healthcare Japan Corporation | 23 |
| eTRAX™ Needle System Starter Kit | Civco Medical Instruments Co., Inc. | 20 |
| Tracking Bracket | Civco Medical Instruments Co., Inc. | 19 |
| Logiq | GE Ultrasound Korea, Ltd. | 18 |
Showing 12 of 805. All products under System, Imaging, Pulsed Echo, Ultrasonic
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Vingmed Ultrasound A/S | 510(k) number | 2024-05-02 | Class II | Device Design | GE HealthCare has become aware of an issue with certain Vivid ultrasound systems where, due to a slow DICOM Worklist response time, incorrect patient name and demographics can be displayed on the ultrasound scanner screen rather than the in | 1 unit | |
| GE Healthcare Austria GmbH & Co OG | 510(k) number | 2023-12-22 | Class II | Device Design | GE HealthCare has become aware of an issue with certain IC9-RS ultrasound probes (see Affected Products List) that can result in a double image artifact creating a ghost image with realistic features. An unrecognized artifact may lead to mi | 12004 units | |
| GE Vingmed Ultrasound A/S | 510(k) number | 2023-05-30 | Class II | Process design | GE HealthCare has become aware that certain Vivid ultrasound systems cannot boot up in a timely fashion. If this occurs, it can delay availability of the device in time-critical emergency situations. | 2 units | |
| GE Vingmed Ultrasound A/S | 510(k) number | 2023-05-30 | Class II | Process design | GE HealthCare has become aware that certain Vivid ultrasound systems cannot boot up in a timely fashion. If this occurs, it can delay availability of the device in time-critical emergency situations. | 14 units | |
| GE Medical Systems, LLC | 510(k) number | 2019-07-02 | Class II | Device Design | Potential for a transducer mis-alignment in certain transvaginal probes. | 3 devices | 2020-10-05 |
| GE Medical Systems, LLC | 510(k) number | 2019-07-02 | Class II | Device Design | Potential for a transducer mis-alignment in certain transvaginal probes. | 2 devices | 2020-10-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.