Innova

Innova IGS 620 002 UDI

Registry build 21.09.26
7manufacturers in China registered for this device type
2catalogue numbers in this listing
10510(k) clearances naming this product code
34recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Beijing (2), Guangdong (2).

Chinese manufacturers registered for FDA product code IZI
Manufacturer City Province Registered as Device types
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Scivita Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 19
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Guangdong Optomedic Technologies, Inc. Foshan Guangdong Manufacturer 7
Zhuhai Dipu Medical Technology Co., Ltd. Zhuhai Guangdong Manufacturer 3

Record

Regulatory record for Innova
Listed by GE Medical Systems, LLC, United States
FDA product code IZI
Device type System, X-Ray, Angiographic
Device class Class 2
Regulation 21 CFR 892.1600
Establishment Specification developer, Manufacturer
510(k) K122457
Record published 2016-09-24
Record revised 2025-08-20 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Distribution end date 2024-05-01

Catalogue Numbers

Catalogue numbers for Innova
Catalogue number Size Status
UPG X100 001 Withdrawn
IGS 620 002 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Sterimed Sterimed, Inc. 114
Med-Syringe Argon Medical Devices, Inc. 16
Control Syringe Argon Medical Devices, Inc. 14
Novadaq and Pinpoint Novadaq Technologies, Inc. 12
DeRoyal Deroyal Industries, Inc. 12
Namic Navilyst Medical, Inc. 9
Namic Medline Industries, Inc. 8
iMRX System Imris Imaging, Inc. 6
System, X-Ray, Angiographic B. Braun Medical Inc. 4
System, X-Ray, Angiographic Intuitive Surgical, Inc. 3
Leica FL800 Leica Microsystems (Schweiz) AG 3
Infrared 800 with Flow® 800 Option Carl Zeiss Meditec Inc 2

Showing 12 of 51. All products under System, X-Ray, Angiographic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K974367 1998-02-13
K973270 1997-11-25
K973368 1997-10-17
K960575 1996-05-07
K945375 1995-01-30
K943355 1994-11-07
K942120 1994-07-18
K941946 1994-05-20
K926258 1993-03-15
K905653 1991-05-15

Recalls Naming This Product

20 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Innova
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC 510(k) number 2019-03-15 Class II Device Design There is a potential for loss of the x-ray imaging function when the user changes field of view (FOV) from 30cm to 20cm or from 20cm to 30cm while releasing the fluoroscopy footswitch pedal simultaneously. 49 devices
GE Medical Systems SCS 510(k) number 2018-03-29 Class II Process control The Discovery IGS and Innova IGS systems may experience X-ray abort errors which could result in the loss of imaging mode before or during fluoroscopic use. 102 devices total 2021-06-15
GE Medical Systems SCS 510(k) number 2018-03-29 Class II Process control The Discovery IGS and Innova IGS systems may experience X-ray abort errors which could result in the loss of imaging mode before or during fluoroscopic use. 102 devices total 2021-06-15
GE Medical Systems, LLC 510(k) number 2015-12-18 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a reported incident in which a Mavig suspension arm with monitor assembly fell to the floor. 2,111 (1078 US; 1033 OUS) 2016-09-07
GE Medical Systems, LLC 510(k) number 2015-11-13 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue related to a non-recoverable loss of displayed imaging (loss of monitor video) involving Optima CL323i & Optima IGS 320 systems. 108 2016-09-07
GE Medical Systems, LLC 510(k) number 2015-11-13 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue related to a non-recoverable loss of displayed imaging (loss of monitor video) involving Optima CL323i & Optima IGS 320 systems. 45 2016-09-07
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 3 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 4 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 13 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 1 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 6 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 2 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 10 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 17 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 6 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 3 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 8 2015-10-28
GE Medical Systems, LLC 510(k) number 2015-05-29 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). 7 2015-10-28
GE Medical Systems, LLC 510(k) number 2014-09-04 Class II Device Design Loss of imaging – affected devices may experience a loss of real-time interventional imaging and/or gantry motion due to the Electromagnetic (EM) sensitivity of the grid detection mechanism. 10 (4 US, 6 OUS). 2015-01-21
GE Medical Systems, LLC 510(k) number 2013-11-15 Class II Software design GE Healthcare has recently become aware of a potential safety issue with respect to IGS 630 Imaging Systems.
While performing fluoroscopy on a biplane fluoroscopy unit, there is a potential for loss of the x-ray imaging function when the us
28 (12 US, 16 OUS). 2014-03-28

Recalls

9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-03-15 Class II Device Design There is a potential for loss of the x-ray imaging function when the user changes field of view (FOV) from 30cm to 20cm or from 20cm to 30cm while releasing the fluoroscopy footswitch pedal simultaneously. 1 device
2019-03-15 Class II Device Design There is a potential for loss of the x-ray imaging function when the user changes field of view (FOV) from 30cm to 20cm or from 20cm to 30cm while releasing the fluoroscopy footswitch pedal simultaneously. 22 devices
2016-11-21 Class II Nonconforming Material/Component GE Healthcare is conducting a recall due to the potential fall of aged CRT monitors – Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems. Total for all products 1,598 (USA 824, OUS 774) 2017-09-26
2016-11-21 Class II Nonconforming Material/Component GE Healthcare is conducting a recall due to the potential fall of aged CRT monitors – Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems. Total for all products 1,598 (USA 824, OUS 774) 2017-09-26
2016-11-21 Class II Nonconforming Material/Component GE Healthcare is conducting a recall due to the potential fall of aged CRT monitors – Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems. Total for all products 1,598 (USA 824, OUS 774) 2017-09-26
2016-11-21 Class II Nonconforming Material/Component GE Healthcare is conducting a recall due to the potential fall of aged CRT monitors – Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems. Total for all products 1,598 (USA 824, OUS 774) 2017-09-26
2011-12-20 Class II Radiation Control for Health and Safety Act It was discovered of a potential failure of the spectral filter mechanism inside the collimator of the innova 3100, innova 3100-IQ and innova 3131-IQ systems. 199 installed in the US 2013-09-18
2011-12-20 Class II Radiation Control for Health and Safety Act It was discovered of a potential failure of the spectral filter mechanism inside the collimator of the innova 3100, innova 3100-IQ and innova 3131-IQ systems. 199 installed in the US 2013-09-18
2011-12-20 Class II Radiation Control for Health and Safety Act It was discovered of a potential failure of the spectral filter mechanism inside the collimator of the innova 3100, innova 3100-IQ and innova 3131-IQ systems. 199 installed in the US 2013-09-18
2011-05-04 Not classified Radiation Control for Health and Safety Act It was discovered that when the Diamentor M4-KDK is installed on an Innova system the dose display is disabled on the certified Innova monitor and enabled on the Diamentor M4-KDK which is not certified as required by FDA regulation
(Subpar
19 2012-03-29
2009-04-16 Not classified Device Design Potential pump failure associated with the Coolix 4000 chiller of the Innova single plane and biplane systems that may stop the chiller from working. If a chiller failure occurs, the user will be informed with a message on the n-room monit 60 2015-12-03
2008-01-14 Not classified Process control Risk of sudden table drop on Omega IV and Omega V tables on GE Healthcare Advantx-E as well as on Innova 2000, 2100IQ, 3100/3100 IQ and 4100/4100IQ cardiovascular X-ray system 252 2011-12-17
2004-03-24 Not classified Other Unintended movements of both the C-arc and the image intensifier have occured due to shearing of the gear motor shaft as a result of the misalignment of the gearbox. 2006-07-24
2004-03-24 Not classified Other Unintended movements of both the C-arc and the image intensifier have occured due to shearing of the gear motor shaft as a result of the misalignment of the gearbox. 2006-07-24
2004-03-24 Not classified Other Unintended movements of both the C-arc and the image intensifier have occured due to shearing of the gear motor shaft as a result of the misalignment of the gearbox. 2006-07-24
2004-03-24 Not classified Other Unintended movements of both the C-arc and the image intensifier have occured due to shearing of the gear motor shaft as a result of the misalignment of the gearbox. 2006-07-24
2004-03-24 Not classified Other Unintended movements of both the C-arc and the image intensifier have occured due to shearing of the gear motor shaft as a result of the misalignment of the gearbox. 2006-07-24

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer