Sedecal

This Portable Diagnostic Radiographic System is intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic…

Registry build 21.09.26

This Portable Diagnostic Radiographic System is intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. (Not for mammography)

5manufacturers in China registered for this device type
20catalogue numbers in this listing
17510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code IZL
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Suzhou Powersite Electric Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for Sedecal
Listed by Sedecal., Sa., Spain
FDA product code IZL
Device type System, X-Ray, Mobile
Device class Class 2
Regulation 21 CFR 892.1720
510(k) K232185
Record published 2023-09-19
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -10 to 40 °C; Storage environment humidity 20 to 85 % RH; Storage environment atmospheric pressure 700 to 1060 millibar; Handling environment temperature 10 to 35 °C; Handling environment humidity 30 to 75 % RH; Handling environment atmospheric pressure 700 to 1060 millibar

Catalogue Numbers

Catalogue numbers for Sedecal
Catalogue number Size Status
SM-IV In distribution
SM-V In distribution
SM-V In distribution
SM-V In distribution
SPL-HF-8.0 In distribution
SM-V In distribution
PhoeniX In distribution
PhoeniX In distribution
SPSL-HF-8.0-APR In distribution
SM-V In distribution
SPL-HF-2.0 In distribution
SM-IV In distribution
SM-IV In distribution
SPL-HF-4.0 In distribution
SM-V In distribution
SPSL-HF-4.0-APR In distribution
SM-IV In distribution
SPSL-HF-8.0 In distribution
SPSL-HF-4.0 In distribution
Soltus 500 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
AcuityPDR RadmediX, LLC 24
Drgem Drgem Corporation 10
DRX-Revolution Mobile X-ray System Carestream Health, Inc. 7
MinXray Minxray, Inc. 6
System, X-Ray, Mobile Ecotron Co., Ltd. 6
MobileDaRt Evolution Shimadzu Corp. 5
Nomad MD™ handheld X-ray system Aribex, Inc. 5
Portable X-ray Unit Ajex Meditech., Ltd. 5
Diagnostic X-ray Unit Poskom Co., Ltd. 4
FDR Aqro Fujifilm Corporation 4
Optima GE Medical Systems, L.L.C. 4

Showing 12 of 75. All products under System, X-Ray, Mobile

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K232185 2023-08-21
K222951 2022-11-21
K221803 2022-07-18
K212291 2021-09-14
K192936 2019-11-15
K192011 2019-09-25
K191813 2019-08-02
K173299 2018-01-26
K161345 2016-07-06
K141895 2014-09-18
K121410 2012-08-02
K101517 2011-08-05
K111725 2011-07-19
K103522 2011-01-26
K090322 2009-03-17
K043002 2004-11-18
K020436 2002-02-22

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Sedecal
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Sedecal S.A. 510(k) number 2022-08-12 Class II Software design Due to un-commanded movement of mobile x-ray unit. 155 systems

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer