Generator, High-Voltage, X-Ray, Diagnostic
Self-Compression Solution
Who Else Makes It
Concentrated in Jiangsu (3), Anhui (1), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Siemens X-RAY Vacuum Technology Ltd. | Wuxi | Jiangsu | Contract manufacturer | 2 |
| Hefei MT Medical Co., Ltd. | Hefei | Anhui | Manufacturer | 23 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| iRay Imaging Technology (Haining) Limited | Haining | Zhejiang | Contract manufacturer | 6 |
| Suzhou Powersite Electric Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Spellman High Voltage Electronics(Suzhou Industrial Park)Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | GE Medical Systems, LLC, United States |
|---|---|
| FDA product code | IZO |
| Device type | Generator, High-Voltage, X-Ray, Diagnostic |
| Device class | Class 1 |
| Regulation | 21 CFR 892.1700 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K162268 |
| Record published | 2017-09-13 |
| Record revised | 2025-11-07 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Handling environment temperature 15 to 40 °C; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment humidity 5 to 95 % RH; Storage environment temperature -40 to 70 °C; Storage environment humidity 5 to 95 % RH; Handling environment atmospheric pressure 50 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5727669 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Varex Imaging | Varex Imaging Corporation | 102 |
| Sedecal | Sedecal., Sa. | 88 |
| Varex Imaging | Varex Imaging Nederland B.V. | 61 |
| Editor HFe | Spellman High Voltage Electronics Corp. | 53 |
| Drgem | Drgem Corporation | 48 |
| S Spellman High Voltage Electronics Corporation | Spellman High Voltage Electronics(Suzhou Industrial Park)Co., Ltd. | 36 |
| iRay | iRay Imaging Technology (Haining) Limited | 25 |
| Delta | Delta Electronics, Inc. Chungli 5 Plant | 22 |
| CMP 200 DR | Communications & Power Industries Canada, Inc. | 17 |
| Indico IQ | Communications & Power Industries Canada, Inc. | 12 |
| Epsilon High Voltage Generator | EMD Technologies Incorporated | 11 |
| UD150B-40 | Shimadzu Corp. | 7 |
Showing 12 of 49. All products under Generator, High-Voltage, X-Ray, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K954666 | 1995-11-24 |
| K943652 | 1994-08-22 |
| K931049 | 1993-05-19 |
| K892943 | 1989-05-22 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems, LLC | 510(k) number | 2025-10-24 | Class II | Radiation Control for Health and Safety Act | Some Senographe Pristina systems either have a missing or an incorrect X-Ray Warning label, which is a nonconformance to FDA Regulation 21 CFR 1020.30(j). | 1,818 (1,580 US; 238 OUS) | |
| GE Medical Systems SCS | 510(k) number | 2023-12-26 | Class II | Radiation Control for Health and Safety Act | X-ray exposure termination audible signal on Senographe Pristina with Efficiency Suite 2 intermittently not emitted per 21CFR 1020.31(j) requirements. | 180 units (60 US; 120 OUS) | |
| GE Medical Systems, LLC | 510(k) number | 2019-05-16 | Class II | Equipment maintenance | Potential slippage of the biopsy positioner when the gantry is rotated during a biopsy procedure. | 82 | 2020-12-16 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2007-03-09 | Not classified | Component change control | GE Healthcare has recently become aware of a potential risk of monitor dropping associated with the monitor suspension of the Advantx system that may impact patient safety. It has been reported that suspensions manufactured after March 8, | 21 | 2012-08-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.