Trinias
31 catalogue numbers from 503-79831-43, listed by Shimadzu Corp., United States, under System, X-Ray, Fluoroscopic, Image-Intensified. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Beijing (2), Guangdong (2), Shanghai (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Ming FAI Enterprise International Co., Ltd. | Kowloon | Hong Kong | Exporter | 18 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Careray Digital Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | Shimadzu Corp., United States |
|---|---|
| FDA product code | JAA |
| Device type | System, X-Ray, Fluoroscopic, Image-Intensified |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1650 |
| 510(k) | K123508 |
| Record published | 2019-05-31 |
| Record revised | 2025-05-28 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 503-79831-43 | In distribution | |
| 503-79830-33 | In distribution | |
| 503-79822-31 | In distribution | |
| 503-79823-43 | In distribution | |
| 503-79832-43 | In distribution | |
| 503-79841-31 | In distribution | |
| 503-79840-43 | In distribution | |
| 503-79820-33 | In distribution | |
| 503-79831-31 | In distribution | |
| 503-79820-31 | In distribution | |
| 503-79821-31 | In distribution | |
| 503-79831-33 | In distribution | |
| 503-79821-33 | In distribution | |
| 503-79830-43 | In distribution | |
| 503-79833-31 | In distribution | |
| 503-79833-32 | In distribution | |
| 503-79832-31 | In distribution | |
| 503-79823-31 | In distribution | |
| 503-79840-31 | In distribution | |
| 503-79401-33 | In distribution | |
| 503-79830-32 | In distribution | |
| 503-79832-32 | In distribution | |
| 503-79401-32 | In distribution | |
| 503-79831-32 | In distribution | |
| 503-79821-32 | In distribution | |
| 503-79402-31 | In distribution | |
| 503-79402-32 | In distribution | |
| 503-79830-31 | In distribution | |
| 503-79402-33 | In distribution | |
| 503-79820-32 | In distribution | |
| 503-79401-31 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Preferred Medical Products, LLC | Preferred Medical Products, LLC | 324 |
| Unbranded | Advance Medical Designs, Inc. | 301 |
| N23 CCD System | Nical SPA | 57 |
| N33 CCD System | Nical SPA | 36 |
| Custom Cover | Advance Medical Designs, Inc. | 15 |
| Pulse | Nuvasive, Inc. | 15 |
| Sonialvision G4 | Shimadzu Corp. | 13 |
| LessRay | Nuvasive, Inc. | 13 |
| Micro Kover | Advance Medical Designs, Inc. | 11 |
| Stephanix | Stephanix | 10 |
| Snap Kover | Advance Medical Designs, Inc. | 9 |
| System, X-Ray, Fluoroscopic, Image-Intensified | Pausch Medical GmbH | 8 |
Showing 12 of 169. All products under System, X-Ray, Fluoroscopic, Image-Intensified
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K191877 | 2019-08-05 |
| K190373 | 2019-03-15 |
| K142341 | 2015-03-06 |
| K131075 | 2014-03-28 |
| K040870 | 2004-05-17 |
| K012424 | 2001-10-18 |
| K933472 | 1994-02-07 |
| K933473 | 1993-11-24 |
| K895394 | 1989-11-13 |
Recalls Naming This Product
8 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Shimadzu Medical Systems | 510(k) number | 2026-04-20 | Class II | Component design/selection | Electromagnetic contactors within high voltage generator may weld together, resulting in current being supplied to power supply even if power is off. | 3487 units | |
| Shimadzu Corporation Medical Systems Division | 510(k) number | 2024-09-06 | Class II | Software Design Change | If digital angiography system is used with a specific catheterization table and the operator directs simultaneous movement of the table and the C-arm using direct memory, then direct memory button is released, the table may continue to move | 13 | |
| Shimadzu Corporation Medical Systems Division | 510(k) number | 2024-01-29 | Class II | Process change control | Due to capacitor manufacturing issue, their is a potential that Flat Panel Device may have abnormal display or no function. | 1 | |
| Shimadzu Medical Systems | 510(k) number | 2021-12-16 | Class II | Process change control | Due to the inadequate adjusting criteria in installation, the system generator on two Digital Angiography Systems, the irradiated x-ray may exceed the x-ray radiation dose rate in fluoroscopic mode. | 28 systems | |
| Shimadzu Medical Systems | 510(k) number | 2020-11-18 | Class II | Software design | The firm has identified a problem with the control software for the celling arm of the X-Ray System. This software issue could cause the ceiling arm of the device to move after the operator has released the movement lever. This could re | 23 units | |
| Shimadzu Medical Systems | 510(k) number | 2019-11-04 | Class II | Device Design | The DAP meters were found to be outside of tolerance. | 3 devices | |
| Shimadzu Medical Systems Usa Com | 510(k) number | 2019-01-14 | Class II | Software design | Two issues: Event 1: Normal operation of the device is to power up the device in the morning, register the first patient, and then perform a fluoroscopy. If, however, the user powers up the device in the morning and makes an error by start | 13 units | 2021-04-30 |
| Shimadzu Medical Systems Usa Com | 510(k) number | 2018-06-15 | Class II | Software design | Due to a software issue the C-arm may unexpectedly moved when being moved to the park position and during specific operations. There is a possibility the C-arm will come into contact with a patient or healthcare personnel. | 1 | 2021-04-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.