Trinias

31 catalogue numbers from 503-79831-43, listed by Shimadzu Corp., United States, under System, X-Ray, Fluoroscopic, Image-Intensified. 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
31catalogue numbers in this listing
9510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (2), Guangdong (2), Shanghai (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JAA
Manufacturer City Province Registered as Device types
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Ming FAI Enterprise International Co., Ltd. Kowloon Hong Kong Exporter 18
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Careray Digital Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for Trinias
Listed by Shimadzu Corp., United States
FDA product code JAA
Device type System, X-Ray, Fluoroscopic, Image-Intensified
Device class Class 2
Regulation 21 CFR 892.1650
510(k) K123508
Record published 2019-05-31
Record revised 2025-05-28 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Trinias
Catalogue number Size Status
503-79831-43 In distribution
503-79830-33 In distribution
503-79822-31 In distribution
503-79823-43 In distribution
503-79832-43 In distribution
503-79841-31 In distribution
503-79840-43 In distribution
503-79820-33 In distribution
503-79831-31 In distribution
503-79820-31 In distribution
503-79821-31 In distribution
503-79831-33 In distribution
503-79821-33 In distribution
503-79830-43 In distribution
503-79833-31 In distribution
503-79833-32 In distribution
503-79832-31 In distribution
503-79823-31 In distribution
503-79840-31 In distribution
503-79401-33 In distribution
503-79830-32 In distribution
503-79832-32 In distribution
503-79401-32 In distribution
503-79831-32 In distribution
503-79821-32 In distribution
503-79402-31 In distribution
503-79402-32 In distribution
503-79830-31 In distribution
503-79402-33 In distribution
503-79820-32 In distribution
503-79401-31 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Preferred Medical Products, LLC Preferred Medical Products, LLC 324
Unbranded Advance Medical Designs, Inc. 301
N23 CCD System Nical SPA 57
N33 CCD System Nical SPA 36
Custom Cover Advance Medical Designs, Inc. 15
Pulse Nuvasive, Inc. 15
Sonialvision G4 Shimadzu Corp. 13
LessRay Nuvasive, Inc. 13
Micro Kover Advance Medical Designs, Inc. 11
Stephanix Stephanix 10
Snap Kover Advance Medical Designs, Inc. 9
System, X-Ray, Fluoroscopic, Image-Intensified Pausch Medical GmbH 8

Showing 12 of 169. All products under System, X-Ray, Fluoroscopic, Image-Intensified

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K191877 2019-08-05
K190373 2019-03-15
K142341 2015-03-06
K131075 2014-03-28
K040870 2004-05-17
K012424 2001-10-18
K933472 1994-02-07
K933473 1993-11-24
K895394 1989-11-13

Recalls Naming This Product

8 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Trinias
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Shimadzu Medical Systems 510(k) number 2026-04-20 Class II Component design/selection Electromagnetic contactors within high voltage generator may weld together, resulting in current being supplied to power supply even if power is off. 3487 units
Shimadzu Corporation Medical Systems Division 510(k) number 2024-09-06 Class II Software Design Change If digital angiography system is used with a specific catheterization table and the operator directs simultaneous movement of the table and the C-arm using direct memory, then direct memory button is released, the table may continue to move 13
Shimadzu Corporation Medical Systems Division 510(k) number 2024-01-29 Class II Process change control Due to capacitor manufacturing issue, their is a potential that Flat Panel Device may have abnormal display or no function. 1
Shimadzu Medical Systems 510(k) number 2021-12-16 Class II Process change control Due to the inadequate adjusting criteria in installation, the system generator on two Digital Angiography Systems, the irradiated x-ray may exceed the x-ray radiation dose rate in fluoroscopic mode. 28 systems
Shimadzu Medical Systems 510(k) number 2020-11-18 Class II Software design The firm has identified a problem with the control software for the celling arm of the X-Ray System. This software issue could cause the ceiling arm of the device to move after the operator has released the movement lever. This could re 23 units
Shimadzu Medical Systems 510(k) number 2019-11-04 Class II Device Design The DAP meters were found to be outside of tolerance. 3 devices
Shimadzu Medical Systems Usa Com 510(k) number 2019-01-14 Class II Software design Two issues:
Event 1:
Normal operation of the device is to power up the device in the morning, register the first patient, and then perform a fluoroscopy. If, however, the user powers up the device in the morning and makes an error by start
13 units 2021-04-30
Shimadzu Medical Systems Usa Com 510(k) number 2018-06-15 Class II Software design Due to a software issue the C-arm may unexpectedly moved when being moved to the park position and during specific operations. There is a possibility the C-arm will come into contact with a patient or healthcare personnel. 1 2021-04-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer