Concentrated in Shanghai (3), Beijing (2), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Orich Medical Equipment (Tianjin) Co., Ltd. | Tianjin | Tianjin | Manufacturer | 5 |
Record
| Listed by | Agfa Healthcare Inc., Canada |
|---|---|
| FDA product code | KPR |
| Device type | System, X-Ray, Stationary |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K012546 |
| Record published | 2016-09-01 |
| Record revised | 2019-06-14 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5420/100 | In distribution | |
| 5420/101 | In distribution | |
| 5420/200 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Drgem | Drgem Corporation | 171 |
| Q-RAD System | Carestream Health, Inc. | 159 |
| DRX – Ascend System | Carestream Health, Inc. | 121 |
| FDR Clinica | Drgem Corporation | 41 |
| RADspeed Pro | Shimadzu Corp. | 31 |
| FDR Visionary Suite | Shimadzu Corp. | 17 |
| Exsys DEXi | Drtech Corporation | 15 |
| Del Medical, Inc. | DEL Medical, Inc. | 15 |
| GXR-Es,ecs Diagnostic X-ray System | Drgem Corporation | 14 |
| X-CEL X-RAY Corporation | Arquilla, Inc. | 14 |
| DRX-Evolution Plus System | Carestream Health, Inc. | 12 |
| Carestream DRX-Evolution | Carestream Health, Inc. | 10 |
Showing 12 of 138. All products under System, X-Ray, Stationary
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Sedecal S.A. | 510(k) number | 2023-12-13 | Class II | Equipment maintenance | Some parts have fallen off the equipment resulting in a safety risk to patients and/or users. | 845 units |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-05-02 | Class II | Labeling design | One of the dent markers from the DX-D600 dropped down from the overhead rail. | 81 units | 2017-04-10 |
| 2014-07-02 | Class II | Device Design | Some customers reported that while using the DX-D600 in room or exam preparation, the Overhead Tube Crane (OTC) showed increased velocity and uncontrolled longitudinal movement. | 17 units | 2015-06-04 |
| 2005-11-18 | Not classified | Other | Users of affected systems may experience a loss of images, the need to repeat the imaging procedure and possibly a short delay in diagnosis. | 1059 units | 2012-01-12 |