EOS®
2 catalogue numbers from 3.3, listed by EOS imaging, France, under System, X-Ray, Stationary. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Beijing (2), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Orich Medical Equipment (Tianjin) Co., Ltd. | Tianjin | Tianjin | Manufacturer | 5 |
Record
| Listed by | EOS imaging, France |
|---|---|
| FDA product code | KPR |
| Device type | System, X-Ray, Stationary |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Manufacturer |
| 510(k) | K152788 |
| Record published | 2016-09-21 |
| Record revised | 2025-02-07 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment temperature 50 to 95 °F; Storage environment humidity 20 to 80 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment temperature 50 to 95 °F; Handling environment humidity 20 to 80 % RH; Handling environment atmospheric pressure 70 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 3.3 | In distribution | |
| 3.4 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Drgem | Drgem Corporation | 171 |
| Q-RAD System | Carestream Health, Inc. | 159 |
| DRX – Ascend System | Carestream Health, Inc. | 121 |
| FDR Clinica | Drgem Corporation | 41 |
| RADspeed Pro | Shimadzu Corp. | 31 |
| FDR Visionary Suite | Shimadzu Corp. | 17 |
| Exsys DEXi | Drtech Corporation | 15 |
| Del Medical, Inc. | DEL Medical, Inc. | 15 |
| GXR-Es,ecs Diagnostic X-ray System | Drgem Corporation | 14 |
| X-CEL X-RAY Corporation | Arquilla, Inc. | 14 |
| DRX-Evolution Plus System | Carestream Health, Inc. | 12 |
| Carestream DRX-Evolution | Carestream Health, Inc. | 10 |
Showing 12 of 138. All products under System, X-Ray, Stationary
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233920 | 2024-08-06 |
| K202394 | 2020-09-16 |
| K192079 | 2019-11-27 |
| K152788 | 2015-10-21 |
| K142773 | 2015-01-22 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2020-12-22 | Class II | Software design | Inadequate images resizing and 2D measurement errors may occur when biplanar acquisition has been performed with patient orientation different from AP (Antero-Posterior). | 11 devices | 2023-05-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.