Philips Radiology Smart Assistant
Catalogue number 1.0, listed by Philips Medical Systems DMC GmbH, Germany, under System, X-Ray, Stationary. 7 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Beijing (2), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Orich Medical Equipment (Tianjin) Co., Ltd. | Tianjin | Tianjin | Manufacturer | 5 |
Record
| Listed by | Philips Medical Systems DMC GmbH, Germany |
|---|---|
| FDA product code | KPR |
| Device type | System, X-Ray, Stationary |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K212186 |
| Record published | 2022-01-18 |
| Record revised | 2025-04-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Distribution end date | 2025-04-15 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1.0 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Drgem | Drgem Corporation | 171 |
| Q-RAD System | Carestream Health, Inc. | 159 |
| DRX – Ascend System | Carestream Health, Inc. | 121 |
| FDR Clinica | Drgem Corporation | 41 |
| RADspeed Pro | Shimadzu Corp. | 31 |
| FDR Visionary Suite | Shimadzu Corp. | 17 |
| Exsys DEXi | Drtech Corporation | 15 |
| Del Medical, Inc. | DEL Medical, Inc. | 15 |
| GXR-Es,ecs Diagnostic X-ray System | Drgem Corporation | 14 |
| X-CEL X-RAY Corporation | Arquilla, Inc. | 14 |
| DRX-Evolution Plus System | Carestream Health, Inc. | 12 |
| Carestream DRX-Evolution | Carestream Health, Inc. | 10 |
Showing 12 of 138. All products under System, X-Ray, Stationary
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233662 | 2024-06-13 |
| K212186 | 2021-12-13 |
| K210692 | 2021-04-02 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-10-01 | Class II | Device Design | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required for manual movement) due to potenti | 12 units |
| 2025-10-01 | Class II | Device Design | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required for manual movement) due to potenti | 284 units |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.