Radiography 7300 C
Radiography 7300 C is a high-end digital radiography system consisting of a height adjustable patient support table and a ceiling suspension consisting of a tube including a control handle…
Radiography 7300 C is a high-end digital radiography system consisting of a height adjustable patient support table and a ceiling suspension consisting of a tube including a control handle used to acquire images with a flat panel fixed RAD detector. Additionally, different vertical stands for the radiography examinations are available. The ceiling suspension can be moved in longitudinal and lateral directions and additionally the tube can be tilted and rotated as well. The proposed Radiography 7300 C is configured with a Philips x-ray generator and a flat panel fixed RAD detector, Pixium 4343RCE. Together with the tube these components form the radiography Image Chain. The additional option of the portable wireless detector i.e. the SkyPlate family can be used for free exposures as well as in the patient support table or in the vertical stand. The proposed Radiography 7300 C uses the following Accessories, • Parking frame for accessories • Handgrips • Side Bar • Adjustable straps • Compression Belt • Infusion Bottle holder TH-S • Infusion Bottle holder TH2 • Support for CPR (Cardio Pulmonary Resuscitation) • Stretch Grip • Remote control holder • Charger 2EZ • Grid’s for Skyplayte Wireless Portable Detectors • Grid’s for Fixed Detectors • Detector Handle • Detector holder for patient bed • Mobile detector holder • Portable panel protector • WPD Hygienic bags • Patient support • Adjustable Straps for Patient Support • Stitching Ruler Radiography 7300C is a successor of DigitalDiagnost C90 (Release Version 1.1). The main differences of Radiography 7300 C versus DigitalDiagnost C90 are optional new features: • Assisted collimation & Assisted detector height alignment (Smart Collimation Thorax / SCT) • Overlays including On-screen collimation & AEC Visualization
Who Else Makes It
Concentrated in Shanghai (3), Beijing (2), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Carestream Health, Inc., Global R&D Center | Shanghai | Shanghai | Specification developer | 8 |
| Philips Healthcare (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Orich Medical Equipment (Tianjin) Co., Ltd. | Tianjin | Tianjin | Manufacturer | 5 |
Record
| Listed by | Philips Medical Systems DMC GmbH, Germany |
|---|---|
| FDA product code | KPR |
| Device type | System, X-Ray, Stationary |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1680 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2024-06-27 |
| Record revised | 2026-05-22 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
| Storage | Storage environment temperature -25 to 70 °C; Storage environment humidity 5 to 95 % RH; Storage environment atmospheric pressure 70 to 110 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 712037 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Drgem | Drgem Corporation | 171 |
| Q-RAD System | Carestream Health, Inc. | 159 |
| DRX – Ascend System | Carestream Health, Inc. | 121 |
| FDR Clinica | Drgem Corporation | 41 |
| RADspeed Pro | Shimadzu Corp. | 31 |
| FDR Visionary Suite | Shimadzu Corp. | 17 |
| Exsys DEXi | Drtech Corporation | 15 |
| Del Medical, Inc. | DEL Medical, Inc. | 15 |
| GXR-Es,ecs Diagnostic X-ray System | Drgem Corporation | 14 |
| X-CEL X-RAY Corporation | Arquilla, Inc. | 14 |
| DRX-Evolution Plus System | Carestream Health, Inc. | 12 |
| Carestream DRX-Evolution | Carestream Health, Inc. | 10 |
Showing 12 of 138. All products under System, X-Ray, Stationary
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233662 | 2024-06-13 |
| K212186 | 2021-12-13 |
| K210692 | 2021-04-02 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Philips Medical Systems DMC GmbH | UDI-DI | 2025-10-01 | Class II | Device Design | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required for manual movement) due to potenti | 284 units |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-10-01 | Class II | Device Design | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required for manual movement) due to potenti | 12 units |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
| 2021-05-19 | Class II | Radiation Control for Health and Safety Act | Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst | 140 systems in total, (Updated 1/30/2023). |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.