Vision

Visaris Vision combines our Visaris Avanse® cleared PACS software (K150725) with all the other components required to make a complete digital diagnostic X‐ray system, including tube stands,…

Registry build 21.09.26

Visaris Vision combines our Visaris Avanse® cleared PACS software (K150725) with all the other components required to make a complete digital diagnostic X‐ray system, including tube stands, tube heads, collimators, generators, tables, and (already cleared) digital X‐ray panels.

7manufacturers in China registered for this device type
4catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (3), Beijing (2), Jiangsu (1).

Chinese manufacturers registered for FDA product code KPR
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Carestream Health, Inc., Global R&D Center Shanghai Shanghai Specification developer 8
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Orich Medical Equipment (Tianjin) Co., Ltd. Tianjin Tianjin Manufacturer 5

Record

Regulatory record for Vision
Listed by Visaris DOO
FDA product code KPR
Device type System, X-Ray, Stationary
Device class Class 2
Regulation 21 CFR 892.1680
510(k) K160620
Record published 2016-10-13
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -20 to 60 °C; Storage environment humidity 10 to 90 % RH; Storage environment atmospheric pressure 500 to 1060 KiloPascal; Handling environment temperature 10 to 30 °C; Handling environment humidity 20 to 80 % RH; Handling environment atmospheric pressure 700 to 1060 KiloPascal

Catalogue Numbers

Catalogue numbers for Vision
Catalogue number Size Status
Vision U In distribution
Vision X In distribution
Vision V In distribution
Vision C In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Drgem Drgem Corporation 171
Q-RAD System Carestream Health, Inc. 159
DRX – Ascend System Carestream Health, Inc. 121
FDR Clinica Drgem Corporation 41
RADspeed Pro Shimadzu Corp. 31
FDR Visionary Suite Shimadzu Corp. 17
Exsys DEXi Drtech Corporation 15
Del Medical, Inc. DEL Medical, Inc. 15
GXR-Es,ecs Diagnostic X-ray System Drgem Corporation 14
X-CEL X-RAY Corporation Arquilla, Inc. 14
DRX-Evolution Plus System Carestream Health, Inc. 12
Carestream DRX-Evolution Carestream Health, Inc. 10

Showing 12 of 138. All products under System, X-Ray, Stationary

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Vision
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Visaris D.O.O. 510(k) number 2018-04-05 Class II Other A failure of the tube arm suspension is possible while the tube arm height is being adjusted. During tube height adjustment there is a small probability of failure of both the primary and redundant holding mechanisms, causing uncontrollabl 8 devices (US), 14 devices (international) 2019-09-19
Visaris D.O.O. 510(k) number 2018-04-05 Class II Other A failure of the tube arm suspension is possible while the tube arm height is being adjusted. During tube height adjustment there is a small probability of failure of both the primary and redundant holding mechanisms, causing uncontrollabl 8 devices (US), 14 devices (international) 2019-09-19
Visaris D.O.O. 510(k) number 2018-04-05 Class II Other A failure of the tube arm suspension is possible while the tube arm height is being adjusted. During tube height adjustment there is a small probability of failure of both the primary and redundant holding mechanisms, causing uncontrollabl 8 devices (US), 14 devices (international) 2019-09-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer