uMI

The FDA summary identifies uMI Panorama models 28 and 35, including the listed uMI Panorama 35. The system combines PET and CT imaging; its PET component measures radiopharmaceutical…

Registry build 21.09.26

The FDA summary identifies uMI Panorama models 28 and 35, including the listed uMI Panorama 35.

The system combines PET and CT imaging; its PET component measures radiopharmaceutical distribution while CT provides anatomical imaging.

Listed Item

Positron Emission Tomography and Computed Tomography System, mobile configuration

System Components

The filing specifies a 280 or 350-millimeter axial field of view for PET paired with a 160-slice CT system. It lists a patient table, power-distribution unit and control and reconstruction system, including a host, monitor and reconstruction computer.

4manufacturers in China registered for this device type
7catalogue numbers in this listing
18510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Beijing (1), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code KPS
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Neusoft Positron Medical Systems Co., Ltd. Shen Yang Liaoning Manufacturer 1

Record

Regulatory record for uMI
Listed by Shanghai United Imaging Healthcare Co., Ltd., China
FDA product code KPS
Device type System, Tomography, Computed, Emission
Device class Class 2
Regulation 21 CFR 892.1200
Establishment Manufacturer
510(k) K223325
Record published 2023-03-20
Record revised 2026-03-18 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Over the counter Yes
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for uMI
Catalogue number Size Status
uMI Panorama 35 In distribution
uMI Panvivo S In distribution
uMI 550 In distribution
uMI Panvivo In distribution
uMI Panorama GS In distribution
uMI Panorama 28 In distribution
uMI 550 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
NeuroQ Syntermed, Inc. 11
Emory Cardiac Toolbox Syntermed, Inc. 10
Discovery GE Medical Systems, L.L.C. 7
Brightonix Brightonix Imaging Inc. 6
UltraSPECT Ultraspect USA, LLC 5
Discovery G E Medical Systems Israel Ltd. 5
Veriton CT Spectrum Dynamics Medical Ltd. 5
Cardius 2 Digirad Corp. 4
Encompass™ SRS Fibreplast™ System Qfix 4
Veriton NM Spectrum Dynamics Medical Ltd. 3
Cedars-Sinai Cardiac Suite Cedars Sinai Medical Center 3
Affinity Hermes Medical Solutions, AB 3

Showing 12 of 172. All products under System, Tomography, Computed, Emission

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261427 2026-07-28
K260524 2026-04-03
K253564 2026-02-13
K251839 2025-07-17
K243538 2024-12-12
K241585 2024-08-30
K241596 2024-08-15
K231762 2024-01-18
K232712 2023-10-03
K231572 2023-07-26
K223325 2023-03-10
K210001 2021-04-30
K210418 2021-04-09
K193210 2020-08-04
K193241 2020-01-26
K182938 2018-12-18
K182237 2018-10-12
K172143 2018-04-13

Recalls Naming This Product

10 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of uMI
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
UIH Technologies, LLC 510(k) number 2025-09-12 Class II Other Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement. 95 units
UIH Technologies, LLC 510(k) number 2025-09-12 Class II Other Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement. 4 unit
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2023-03-01 Class II Software design Due to a software issue where the process of patient scanning, the scatter correction may occasionally fail with will potentially cause a failure of the PET image reconstruction and generation of PET images. 47 systems (U.S. only)
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2022-05-30 Class II Device Design The wireless VSM module of a mobile PET/CT system, operating in an environment with strong Wi-Fi signals, may experience ECG signal and respiratory signal loss due to Wi-Fi interference. ECG and respiratory signal loss during acquisition ca 32
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2021-08-02 Class II Device Design The EXAM acquisition workflow could occasionally freeze after canceling the PET scan. 23 systems
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2021-08-02 Class II Device Design The EXAM acquisition workflow could occasionally freeze after canceling the PET scan. 1 system
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2020-08-05 Class II Software design A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during
multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.
9
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2020-07-16 Class II Device Design 1) Service function problem may cause false marking of a bad channel resulting in ring artifacts; 2) Potential intermittent scout scanning interruption due to angle signal drift caused by external interference; 3) Metal edge overlap of myla 4 units 2022-07-07
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2020-03-26 Class II Software design In affected software version, of Positron emission tomography and computed tomography system, the CT Hounsfield unit curve may not display in real time when using the bolus tracking protocol with the tracker scan function. If this occurs, t 3 2023-08-02
Shanghai United Imaging Healthcare Co., Ltd. 510(k) number 2019-08-26 Class II Software design Potential sporadic software bugs in R001.3.0.0.750505 software version may cause an issue with the PET acquisition raw data causing reconstruction problems during PET/CT scanning and could possibly cause rescans of patients with additional 2 units 2022-05-18

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-07-16 Class II Device Design 1) 1) Potential intermittent issue may cause image data problems, may lead to artifacts; 2) Potential intermittent scout scanning interruption due to angle signal drift caused by external interference; 3) Metal edge overlap of mylar strip i 1 unit distributed to Texas 2022-07-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer