System, Nuclear Magnetic Resonance Imaging

SIGNA Artist System Medical Device Assembly-MDR

Registry build 21.09.26
12manufacturers in China registered for this device type
16catalogue numbers in this listing
6510(k) clearances naming this product code

Who Else Makes It

Concentrated in Shanghai (3), Beijing (2), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LNH
Manufacturer City Province Registered as Device types
Shanghai Chenguang Medical Technologies Co., Ltd. Shanghai Shanghai Contract manufacturer 2
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
GE Healthcare (Tianjin) Company Limited Tianjin Tianjin Specification developer 5
GE Healthcare (China) Co., Ltd. – Tianjin Tianjin Tianjin Specification developer 3
Shenzhen RF Tech Co., Ltd. Shenzhen Guangdong Complaint-file establishment 2
Shanghai Chenshi Medical Instruments Co., Ltd. Shanghai Shanghai Exporter 2
MRI Division, Beijing Wandong Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1
Jiangsu Magspin Instrument Co., Ltd. Kunshan Jiangsu Manufacturer 1
Xingaoyi Medical Equipment Co., Ltd. Yuyao Zhejiang Manufacturer 1
Sino Canada Health Engineering Research Institute (Hefei) Ltd. (Scheri) Hefei Anhui Complaint-file establishment 1

Record

Regulatory record for System, Nuclear Magnetic Resonance Imaging
Listed by GE Healthcare (Tianjin) Company Limited, China
FDA product code LNH
Device type System, Nuclear Magnetic Resonance Imaging
Device class Class 2
Regulation 21 CFR 892.1000
Establishment Specification developer, Manufacturer
510(k) K251399
Record published 2025-09-26
Record revised 2026-01-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for System, Nuclear Magnetic Resonance Imaging
Catalogue number Size Status
SIGNA Sprint In distribution
1.5T EXPRESS COIL – 16E HEAD NECK ARRAY In distribution
SIGNA Victor In distribution
SIGNA Voyager In distribution
SIGNA Creator In distribution
SIGNA Artist In distribution
1.5T EXPRESS COIL – 9E ANTERIOR ARRAY In distribution
SIGNA Artist In distribution
SIGNA Explorer In distribution
Upgrade Kit to SIGNA Explorer In distribution
SIGNA Creator In distribution
SIGNA Voyager In distribution
SIGNA Artist In distribution
SIGNA Explorer In distribution
SIGNA Artist In distribution
SIGNA Prime In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ingenia Philips Medical Systems Nederland B.V. 72
System, Nuclear Magnetic Resonance Imaging GE Medical Systems, L.L.C. 40
System, Nuclear Magnetic Resonance Imaging Medtronic Navigation, Inc. 23
Uni-frame® Thermoplastic Medtec LLC 19
Positioning Cushion Medtec LLC 18
Posicast® Thermoplastic Medtec LLC 18
Invivo Philips DS North America LLC 15
Type-S™ Thermoplastic Medtec LLC 14
Aperto Lucent Fujifilm Corporation 13
MRI Integral “T” with Check Valve for Medrad® Spectris MR Injector Bayer Medical Care Inc. 11
PPG Finger Band IVY Biomedical Systems, Inc. 11
Vac-Lok™ Cushion Medtec LLC 10

Showing 12 of 478. All products under System, Nuclear Magnetic Resonance Imaging

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233728 2024-01-19
K223439 2023-02-13
K213603 2022-02-11
K211980 2022-01-16
K202238 2020-09-04
K192426 2019-10-01

Recalls Naming This Product

63 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of System, Nuclear Magnetic Resonance Imaging
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 760 units
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 280 units
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 19 units
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 1372 units
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 758 units
GE Medical Systems, LLC 510(k) number 2025-06-20 Class II Equipment maintenance GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET 330 units
GE Medical Systems, LLC 510(k) number 2025-05-23 Class II Device Design GE HealthCare has become aware that gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. As a result, acoustic levels can exceed 99
GE Healthcare (China) Co., Ltd. 510(k) number 2025-01-31 Class II Software design For certain MR systems, a scan can be resumed following a Power Monitor trip when the “6-minute average SAR” is above the limit indicated on the “SAR Display”. The user interface may incorrectly enable a scan to proceed earlier than intende 2538
GE Healthcare (China) Co., Ltd. 510(k) number 2025-01-31 Class II Software design For certain MR systems, a scan can be resumed following a Power Monitor trip when the “6-minute average SAR” is above the limit indicated on the “SAR Display”. The user interface may incorrectly enable a scan to proceed earlier than intende 22
GE Healthcare (China) Co., Ltd. 510(k) number 2025-01-31 Class II Software design For certain MR systems, a scan can be resumed following a Power Monitor trip when the “6-minute average SAR” is above the limit indicated on the “SAR Display”. The user interface may incorrectly enable a scan to proceed earlier than intende 33
GE Healthcare (China) Co., Ltd. 510(k) number 2025-01-31 Class II Software design For certain MR systems, a scan can be resumed following a Power Monitor trip when the “6-minute average SAR” is above the limit indicated on the “SAR Display”. The user interface may incorrectly enable a scan to proceed earlier than intende 241
GE Medical Systems, LLC 510(k) number 2024-10-28 Class II Device Design Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. 8 units
GE Medical Systems, LLC 510(k) number 2024-10-28 Class II Device Design Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. 53 units
GE Medical Systems, LLC 510(k) number 2024-10-28 Class II Device Design Gradient coils for certain MR systems (see affected product list in this letter), under specific conditions, can produce elevated acoustic noise during scanning. 3 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
834 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
484 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
724 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
23 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
1607 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
1228 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
1528 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
1817 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
2528 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
308 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
81 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
375 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
469 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
72 units
GE Medical Systems, LLC 510(k) number 2024-06-14 Class II Device Design GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met:
1. 2D FSE T2 FLAIR OR T2 FLAIR
23 units
GE Medical Systems, LLC 510(k) number 2022-03-04 Class II Nonconforming Material/Component During the de-installation of an MR system magnet, if all rigging and hardware that attach to the magnet for transportation are not properly installed and secured, the magnet may fall, leading to potential injury. 18,411 systems
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-12-23 Class II Process control The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. 17,228 devices total in this field correction
GE Medical Systems, LLC 510(k) number 2021-08-26 Class II Software design Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images. 2 devices 2026-05-04

Showing 40 of 63.

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P860010 1988-06-12 INSTRUMENTARIUM ULF MR IMAGING SYSTEM Palomex Instrumentarium Corp.
P860062 1988-05-25 RESONEX RX4000{TM} MAGNETIC RESONANCE IMAGING SYST Resonex, Inc.
P850043 1987-12-30 MAGNISCAN 5000 MRI SYSTEM Thomson-Cgr Medical Corp.
P830074 1987-11-25 GE SIGNA MAGNETIC RESONANCE DIAGNOSTIC IMAGING SYS General Electric Co.
P840063 1987-08-11 GYROSCAN(TM) Philips Medical Systems Technologies Ltd
P840007 1987-04-02 GYREX, MODELS S3500 & S5000 Elscint, Inc.
P830076 1986-10-08 FONAR NMR WHOLE BODY SCANNER BETA 3000 Fonar Corp.
P830052 1986-05-28 NUCLEAR MAGNETIC RESONANCE SCANNER MODELS NMR 1000 Philips Medical Systems (Cleveland), Inc.
P830051 1986-04-30 TESLACON(TM) NMR IMAGING SYSTEM Technicare Corp.
P830053 1985-12-18 DIASONICS NMR IMAGING SYSTEM Diasonics, Inc.
P830081 1985-06-06 MAGNETOM Siemens Healthcare Limited

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer