Magnetom Sempra
Catalogue number 10840815, listed by Siemens Shenzhen Magnetic Resonance Ltd., China, under System, Nuclear Magnetic Resonance Spectroscopic. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Tianjin (2), Beijing (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| GE Healthcare (Tianjin) Company Limited | Tianjin | Tianjin | Specification developer | 5 |
| GE Healthcare (China) Co., Ltd. – Tianjin | Tianjin | Tianjin | Specification developer | 3 |
Record
| Listed by | Siemens Shenzhen Magnetic Resonance Ltd., China |
|---|---|
| FDA product code | LNI |
| Device type | System, Nuclear Magnetic Resonance Spectroscopic |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1000 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2018-03-06 |
| Record revised | 2024-10-07 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10840815 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| System, Nuclear Magnetic Resonance Spectroscopic | GE Healthcare (Tianjin) Company Limited | 6 |
| Ingenia | Philips Medical Systems Nederland B.V. | 3 |
| System, Nuclear Magnetic Resonance Spectroscopic | Usa Instruments, Inc. | 2 |
| Magnetom Cima.X | Siemens Healthcare Limited | 2 |
| Magnetom Altea | Siemens Healthineers AG | 2 |
| 1.5T 32-ch Head Coil MR Coil | Siemens Healthcare Limited | 1 |
| CP Flex Coil Large 63 047 | Siemens Healthcare Limited | 1 |
| Magnetom Sola | Siemens Healthineers AG | 1 |
| Hitachi | Hitachi, Ltd. | 1 |
| Breast Array CPL. 047 | Siemens Healthcare Limited | 1 |
| Achieva | Philips Medical Systems Nederland B.V. | 1 |
| 1.5T Loop 7 cm MR coil kit | Siemens Healthcare Limited | 1 |
Showing 12 of 85. All products under System, Nuclear Magnetic Resonance Spectroscopic
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Siemens Medical Solutions USA, Inc. | UDI-DI | 2023-09-01 | Class II | Process control | In some cases, when lubricating grease is present within the headband of the over-ear headphones, it may cause visible, dot- or lineshaped, fat-isointense artifacts during head examinations only. These potential artifacts depend on the posi | 3,470 units US; 13,265 worldwide |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.